Use and Care Manual
www.usaprocom.com
11200230-01A
INSTALLATION
DO NOT use an off the shelf 3/8" 
NPT pipe plug. This will damage 
the plungers located inside the 
regulator.
DO NOT try to remove the plung-
ers from inside the regulator. The 
plunger will be pushed back as 
the tting is installed. 
Make sure the type of gas being 
used is correct. Check to make 
sure the connection tting is in 
the correct inlet on the regula-
tor. Refer to Connecting to Gas 
Supply, page 14.
If you  are using  natural gas 
and the pilot will not light, see 
Troubleshooting, page 24.
Use only the cap supplied on the 
regulator. Do not use an off the 
shelf pipe plug. This can damage 
the plunger. The supplied regula-
tor cap is designed so it will not 
engage the unused gas type.
4.  Apply  thread  sealant  to  the  threads  on 
the connection tting. While pushing in, 
rotate the tting clockwise until the threads 
engage the regulator. After the tting has 
been  hand  tightened  into  the  regulator 
use a wrench to complete tightening of the 
tting. Install additional tting to connect 
to the house supply.
Metal Cap
Metal Cap
DO NOT REMOVE
Yellow Natural Gas Plunger
Install Gas Fitting Here
2.  Apply  thread  sealant  to  the  threads  on 
the  connection  tting.  While pushing  in, 
rotate the tting clockwise until the threads 
engage the regulator. After the tting has 
been  hand  tightened  into  the  regulator 
use a wrench to complete tightening of the 
tting. Install additional tting to connect 
to the house supply.
FOR NATURAL GAS (NG) 
INSTALLATION: YELLOW
1.  Remove  the  blue  dust  cover  from  the 
regulator.
2.  Remove the metal cap installed over the 
NG regulator inlet.
3.  Install metal cap over LP/Propane regulator 
inlet. This will keep debris out of regulator.
Side of Fireplace