Use and Care Manual

www.usaprocom.com
19200159-01A
OPERATION
Shutting Off Heater
Turn control knob clockwise to the
OFF position.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise to the
PILOT position.
1. Remove screen by lifting and pulling
forward.
2. Follow steps 1 through 5 under Lighting
Instructions, page 18.
3. With control knob in PILOT position, strike
match, and hold near pilot. Press in control
knob; pilot should light.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
5. Make sure the heater screen is in place
before operating heater.
THERMOSTAT CONTROL OPERATION
The thermostatic control used on this model
differs from standard thermostats. Standard
thermostats simply turn the burner on and off.
The thermostat used on this heater senses the
room temperature. At times the room may ex-
ceed the set temperature. If so, the burner will
shut off. The burner will cycle back on when
room temperature drops below the set tem-
perature. The control knob can be set to any
comfort level between HIGH (5) and LOW (1).
Note: The thermostat sensing bulb measures
the temperature depending on housing con-
struction.
TO TURN OFF GAS TO APPLIANCE
MANUAL LIGHTING PROCEDURE