Use and Care Manual

18
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information on the side of the heater.
2. Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise to the OFF position.
4. Wait ve (5) minutes to clear out any gas. Then smell for gas, including near the oor. If you smell gas, STOP! Do
not try to light any appliance. Do not touch electrical switch or use any phone in the building. Immediately contact
gas supplier from a neighbor’s phone. Follow gas supplier’s instructions. If you can’t reach the gas supplier, call the
re dept. If you don’t smell gas, go to the next step.
5. Turn control knob counterclockwise to the PILOT position.Press in control knob for ve (5) seconds (see Figure
19).
Note: The rst time that the heater is operated after connecting the gas supply,the control knob should be depressed
for about thirty (30) seconds.This will allow air to bleed from the gas sysystem. If pilot does not stay lit, refer to
Troubleshooting, pages 21 through 23. Also contact a qualied service technician or gas supplier for repairs. Until
repairs are made, light pilot with match.
• If control knob does not pop up when released, contact a qualied service technician or gas supplier for repairs.
6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to
the front of burner. The pilot can be seen through the gill. If needed, keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to Troubleshooting, pages 21 through 23. Also contact a qualified service
technician or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see “Manual
Lighting Procedure”.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
If control knob does not pop up when released, contact a qualied service technician or gas supplier for repairs.
Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute
before lighting pilot again.
8. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to
any heat level between 1 and 5.
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
Figure 19 - Control Knob in the
OFF Position
THERMOSTAT CONTROL OPERATION
The thermostatic control used on this model differs from standard ther-
mostats. Standard thermostats simply turn the burner on and off. The
thermostat used on this heater senses the room temperature. At times
the room may exceed the set temperature. If so, the burner will shut
off. The burner will cycle back on when room temperature drops below
the set temperature. The control knob can be set to any comfort level
between HIGH (5) and LOW (1).
TO TURN OFF GAS TO APPLIANCE
Fig. 20
Shutting Off Heater
Turn control knob clockwise to the OFF position.
Shutting Off Burner Only (pilot stays lit )
Turn control knob clockwise to the PILOT position.
CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve. Slightly press in control
knob and turn counterclockwise to your desired heat
level (1, 2, 3, 4, or 5). (see Fig. 20)