Installation Guide
www.usaprocom.com
200199-01B12
INSTALLATION
CONNECTING TO GAS SUPPLY
  CAUTION: For natural gas, 
check your gas line pressure 
before connecting heater to gas 
line. Gas line pressure must be 
no greater than 9.5" of w.c. If gas 
line pressure is higher, heater 
regulator damage could occur.
 CAUTION: Avoid damage to 
regulator. Hold gas regulator 
with wrench when connecting 
into gas piping and/or ttings.
 CAUTION: Use pipe joint 
sealant that is resistant to gas 
(Propane/LP or Natural Gas).
Before installing heater, make sure you have 
the items listed below:
•  external regulator for propane/LP unit only 
(supplied by installer)
•  piping (check local codes)
•  sealant (resistant to natural gas and pro-
pane/LP gas)
•  equipment shutoff valve*
•  test gauge connection*
•  sediment trap
•  tee joint 
•  pipe wrench
•  exible gas hose (check local codes) 
•  3/8" NPT brass tting
* A  CSA  design-certied  equipment  shutoff 
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase 
the optional CSA design certied equipment 
shutoff valve from your dealer.
Typical Inlet Pipe Diameters
Use 1/2" black iron pipe or greater. Installa-
tion must include an equipment shutoff valve, 
union, and plugged 1/8" NPT tap. Locate NPT 
tap within reach for test gauge hook up. NPT 
tap must be upstream from heater (see Figure 
8, page 13).
IMPORTANT: Install an equipment shutoff 
valve in an accessible location. The equip-
ment shutoff valve is for turning on or shutting 
off the gas to the appliance.
  WARNING: A  qualied  ser-
vice technician must connect 
heater to gas supply. Follow all 
local codes.
 WARNING: This appliance 
requires a  3/8" NPT (National 
Pipe Thread) inlet connection to 
the pressure regulator.
 WARNING: For natural gas, 
Never connect heater to private 
(non-utility) gas wells. This gas 
is commonly known as wellhead 
gas.
 CAUTION: For propane/LP 
gas, never connect heater direct-
ly to the gas supply. This heater 
requires an external regulator 
(not supplied). Install the external 
regulator between the heater and 
propane/LP gas supply. Gas sup-
plier provides external regulator 
for natural gas. The installer 
provides the external regulator 
for propane/LP gas.
 WARNING: Do not over-
tighten gas connections.
 CAUTION: Use only new, 
black  iron  or  steel  pipe.  Inter-
nally tinned copper tubing may 
be used in certain areas. Check 
your local codes. Use pipe of 
1/2" diameter or greater to allow 
proper gas volume to heater. If 
pipe is too small, undue loss of 
pressure will occur.