WARNING: You must operate
this heater with the door closed
and in the locked position. Make
sure screen is installed before
running heater.
NOTICE: During initial operation of
new heater, burning logs will give
off a paper-burning smell. Orange
ame will also be present. Open
damper or window to vent smell.
This will only last a few hours.
1. STOP! Read the safety information above.
2. Make sure equipment shutoff valve is fully
open.
3. Push in control knob slightly and turn
clockwise to the OFF position.
4. Wait ve (5) minutes to clear out any gas.
Then smell for gas around heater and near
the oor. If you smell gas, STOP! Follow
"B" in the safety information above. If you
do not smell gas, go to the next step.
5. Turn control knob counterclockwise
to the PILOT position. Press in control
knob for ve (5) seconds.
Note: The rst time that the heater is oper-
ated after connecting the gas supply, the
control knob should be pressed for about
thirty (30) seconds. This will allow air to
bleed from the gas system. If pilot does not
stay lit, refer to Troubleshooting, pages 26
though 28. Also contact a qualied service
technician or gas supplier for repairs. Until
repairs are made, light pilot with match.
If control knob does not pop up when
released, contact a qualified service
technician or gas supplier for repairs.
6. With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached to
the rear of the burner. If needed, keep
pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, page 26. Also contact a
qualied service technician or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure, page 19.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to the desired heating level. The main
burner should light. Set control knob to
any heat level between HI (5) and LO (1).
Note: Please wait one minute after shut-
ting off replace to allow the control valve
to reset before starting again.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: If input gas
type is NG, make sure NG pilot
burner ignites. If input gas type
is LP, make sure LP pilot burner
ignites.
MODEL PCSD25T
LIGHTING INSTRUCTIONS
Ignitor
Button
Control Knob
Figure 18 - Ignitor Button and Control
Knob Locations