Operating instructions
15 
Go to (0) % if 
(Mode) = (Eve) 
Enter the percent of the close position that you want the shade system to go to during heat retention. Also, select 
the mode of operation desired to initiate the heating retention program. 
And 
(Air Temp 1) >= 80 
Select the sensor, and the setting to be used (if any) to also activate the shade system for heat retention. You 
may also choose to ignore any sensors if you like. This will activate the system simply on modes of operation 
(DAY, MID, EVE, NGT) 
Cancel HeatRet 1 
If (Mode) = (Day) 
Select the mode of day (Day, Midday, Evening, or Night) to cancel the heat retention feature. 
OR 
Air Temp 1 (<=) (60) 
Select the temperature and the setting to cancel the heat retention mode. 
Max Pos (Uncov’d) 
If Vent 1 Active 
Use this if the shade materials in use do not allow air passage and it is desired to always leave the shade system 
slightly open when the roof ventilation system is operating. This will allow an airflow path. 