Installation Guide
www.usaprocom.com
200068-01A20
 WARNING: You  must  oper-
ate this heater with the screen 
in  place.  Make  sure  screen  is 
installed before running heater.
NOTICE: During initial operation 
of new heater, burning logs will 
give off a paper-burning smell. 
Orange ame will also be pres-
ent. Open damper or window to 
vent smell. This will only last a 
few hours.
1.  STOP!  Read  the  safety  information, 
page 19.
2.  Make sure equipment shutoff valve is fully 
open.
3.  This gas log set is equipped with an igni-
tion  device  (piezo)  which  automatically 
lights  the  pilot.  If  the  piezo  ignitor  does 
not  light  the  pilot,  see  Manual Lighting 
Procedure, page 21.
4.  Turn control knob clockwise   to the 
OFF position. Set the ame control to the 
lowest setting.
5.  Wait ve (5) minutes to clear out any gas. 
Then smell for gas around heater and near 
the oor. If you smell gas, STOP! Follow 
"B" in the safety  information, page 19. If 
you do not smell gas, go to the next step.
6.  From the OFF position, turn the  control 
knob counterclockwise   to the IGN 
position. Press in control knob for ve (5) 
seconds.
  Note:  The  rst  time  that  the  heater  is 
operated after connecting the gas supply, 
the control knob should be pressed for 
about thirty (30) seconds. This will allow 
air to bleed from the gas system. If pilot 
does not stay lit, refer to Troubleshooting, 
pages 25 though 28. Also contact a quali-
ed service technician or gas supplier for 
repairs. Until repairs are made, light pilot 
with match.
• If  control  knob  does  not  pop  up  when 
released,  contact  a  qualified  service 
technician or gas supplier for repairs.
7.  With  control  knob  pressed  in,  push 
down  and  release  ignitor  button.  This 
will  light  pilot.  The  pilot  is  attached  to 
the  rear  of  the  burner.  If  needed,  keep 
pressing  ignitor  button  until  pilot  lights. 
Note: If pilot does not stay lit, refer to 
Troubleshooting, pages 25 though 28. 
Also contact a qualied service technician 
or gas supplier for repairs. Until repairs 
are made, light pilot with match. To light 
pilot with match, see Manual Lighting 
Procedure, page 21.
8.  Keep control knob pressed in for 60 sec-
onds to prevent the ame detector from 
shutting  off  the  gas  while  the  probe  is 
warming up. The exciter ring on the pilot 
tube must glow red before the burners can 
be lit. After 60 seconds,  release  control 
knob.
  Note: If pilot goes out, repeat steps 4 
through 8. Wait one (1) minute before 
lighting pilot again.
9.  Turn control knob counterclockwise   
to  the  ON  position.  The  main  burner 
should light.
  Note: Please wait one minute after shut-
ting off heater to allow the control valve 
to reset before starting again.
10. After the pilot has been lit for one minute, 
the burners  can  be  turned on. Turn  the 
ON/OFF switch to the ON position or ad-
just the thermostat to the desired setting.
MILLIVOLT CONTROL MODELS (MVA)
LIGHTING INSTRUCTIONS
OPERATION
Ignitor 
Button
Manual/
Remote 
Switch
Control 
Knob
Flame
Control 
Knob
Figure 28 - Ignitor Button and Control 
Knob Locations