Blood Glucose Monitoring System Owner’s Manual
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Dear Prodigy Pocket® Meter Owner: Thank you for choosing the Prodigy Pocket® meter as your blood glucose monitoring system. Please read this manual carefully as it contains important information about your new Prodigy® system. A warranty registration card is included with your system. Please return the completed card to us or complete warranty online at www.prodigymeter.com.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Table of Contents Viewing Results on a Personal Computer...................48 Caring for your Prodigy® Meter...............................49-52 Cleaning your System................................................ 49 Lancing Device ........................................................... 49 Disinfecting your System..................................... 49-50 Storing your System...................................................
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Important Safety Instructions Read this before using your Prodigy meter. The following basic safety precautions should always be taken. ® • Your Prodigy® meter, test strips, lancets and lancing device are for single patient use only. Do not share them with anyone, including other family members. Do not use on multiple patients.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Important Health-Related Information “CDC Clinical Reminder: Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting Blood-borne Pathogens” (2010) http://cdc.gov/injectionsafety/FingerstickDevicesBGM.html Severe dehydration and excessive water loss may cause false low results. If you believe you are suffering from severe dehydration, consult a healthcare professional immediately.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Test results below 60 mg/dL (3.3 mmol/L) indicate low blood glucose (hypoglycemia). Test results greater than 240 mg/dL (13.3 mmol/L) indicate high blood glucose (hyperglycemia). If your results are below 60 mg/dL or above 240 mg/dL, repeat the test, and if the results are still below 60 mg/dL (3.3 mmol/L) or above 240 mg/dL (13.3 mmol/L), consult your healthcare professional immediately.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter When to use AST? Food, medication, illness, stress and exercise can affect blood glucose levels. Capillary blood at the fingertip reflects these changes faster than capillary blood at other sites. Therefore, if you are testing your blood glucose level during or immediately after a meal, physical exercise or stressful event, take the blood sample from your fingertip only.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter About Prodigy® Test Strips Key Functions of the Test Strip All Prodigy® meters measure the amount of sugar in the blood, commonly referred to as blood glucose. Blood is applied to the opening of the absorbent channel on the end of the test strip and is automatically drawn into the test strip.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter solution sample to the test strip’s absorbent channel. Applying other substances to the test strip’s absorbent channel will cause inaccurate results. • Record the discard date on the vial label when you first open it. Discard remaining test strips 90 days after the first opening date. • Do not use test strips beyond the expiration date printed on the package.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Prodigy® meters, test strips and control solutions have been designed, tested and proven to work together as a system to produce accurate blood glucose test results. Important: Use only Prodigy® control solutions and test strips with your Prodigy® meter. Using other test strips and control solutions with this meter can produce inaccurate results.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Setting up the Prodigy Pocket® Meter Meter Display Key Functions of the Meter Test Strip Slot Insert the test strip here. The meter will turn on automatically. Test Result Area Displays test results. LCD Display Guides you through the test using symbols and simple messages. Main Button Turns the meter on or performs other functions described in this manual.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Meter Display Low Battery Symbol Appears when the battery power is low. Temperature Symbol Appears when temperature is outside of operating range. STEP 1: Insert the Battery Open the battery cover located on the backside of the meter. Insert one (1) 3 Volt CR2032 lithium battery. The meter should beep, turn on and enter Setting Mode.See Figure 8. Figure 7 Memory Symbol Appears when you review the memory.
PRODIGY Pocket® Blood Glucose Meter With the correct year on the display, (See Figure 9) press the “SET” button and the date will appear on the display with the month segment flashing. See Figure 10. STEP 4: Set the Month Press and release the “M” button to advance the month. With the correct month on the display, press the “SET” button and the date segment will start flashing. See Figure 11. PRODIGY Pocket® Blood Glucose Meter STEP 6: Set the Hour Press and release the “M” button to advance the hour.
PRODIGY Pocket® Blood Glucose Meter STEP 8: Unit of Measure Press and hold the “M” button until the unit of measurement you are choosing appears on the display. See Figures 14 and 15. PRODIGY Pocket® Blood Glucose Meter The “- - -” image will appear on the LCD screen to indicate that all memory has been deleted. Setup is now completed. “OFF” is displayed and the meter turns off.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Control Solution Testing If your Prodigy® control solution did not come with a Prodigy® Control Solution Insert, the following information shall take the place of the insert. Product Numbers: 990310 (Low) 53310 (Low) 53350 (High) Intended Use: Prodigy® control solution is a red liquid that contains glucose that will react with test strips and produce a test result.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter • When you begin using a new vial of test strips. • When test strips have been exposed to extreme environmental conditions. • If you drop the meter. • If you change the battery in the meter. Storage and Handling: • Store the control solution tightly closed at temperatures below 86°F (30°C). • Do not refrigerate. Do not store in your car. Nonreactive Ingredients (% w/v) 99.95 99.81 Owner’s Manual Start with the meter off.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Important: Be sure that you are in control solution mode so that the test result will not be stored in the meter memory. STEP 4: Apply Control Solution 1. Check the expiration and discard dates on your control solution and test strip vials. 2. Shake the control solution bottle well, then remove cap. 3. Squeeze the bottle and discard the first drop then wipe the dispenser tip with clean tissue paper or cotton. 4.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Questionable Results: If the test result falls outside the range printed on the test strip vial, check the “Trouble-Shooting Guide” located in the “System Troubleshooting” section of this manual and repeat the test. Caution: Do not use test strips or control solution that have exceeded the discard date, are expired or have been damaged. Your results may be inaccurate.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Performing a Blood Glucose Test until the number lines up with the arrow. Choose from the following depths: 1-2 (least penetration) for soft, 3 (average penetration) for average, 4-5 (deepest penetration) for thick or calloused skin. See Figure 25. Preparing the Lancing Device STEP 1: Remove the cap of the lancing device by twisting it off. See Figure 22.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter *The lancing device is prepared and ready to lance your finger for a blood sample. Getting a Blood Sample STEP 1: Wash Your Hands and Puncture Site Use warm, soapy water. Rinse and dry your hands thoroughly. STEP 2: Select and Lance a Puncture Site • Fingertip Hold the lancing device firmly against the side of your finger. Press the release button. You will hear a click, indicating that the puncture is Figure 27 complete.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Warning: The first drop of blood usually contains tissue fluid and serum, which may affect the test result. It should be discarded. Applying Blood to the Strip STEP 1: Insert the Test Strip Insert a test strip with the contact bar end entering into the test slot first. Push the test strip as far as it will go without bending it. The meter turns on automatically. See Figure 31.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter STEP 3: Read Your Result After the meter counts down from 6 to 1, your blood glucose test result appears along with the unit of measure, date and time. This blood glucose result is automatically stored in the meter memory. Turn the meter off by removing the test strip. Discard the used test strip carefully to avoid contamination. See Figure 34. You will have to use a new test strip.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Using the Meter Memory The Prodigy Pocket stores the 120 most recent blood glucose test results with date and time in its memory. It also provides you with 7, 14 and 28– day averages of your blood glucose test results. You can review the individual or average test results by entering the memory mode. ® STEP 1: Enter the Memory Mode While the meter is turned off, press the “M” button to turn the meter on.
PRODIGY Pocket® Blood Glucose Meter Each time you press and release the “M” button, the meter will recall up to your last 120 test results in order. See Figure 38. When the memory is full, the oldest result is deleted as the newest is added. After reaching the last set of results, press the “M” button and the meter turns off. See Figure 39. PRODIGY Pocket® Blood Glucose Meter Specifications Dimensions: 3.54 in. (L) x 1.38 in. (W) x 0.83 in. (H) 90 mm (L) x 35 mm (W) x 21 mm (H) Weight: 1.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Viewing Results on a Personal Computer Caring for your Prodigy® Meter Test results in your meter’s memory can be transmitted to your personal computer. Please visit the Prodigy® website, www.prodigymeter.com for the latest instructions.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter device should be decontaminated prior to use by the second person. Battery The Prodigy Pocket® meter comes with one (1) CR2032 lithium battery. Batteries are manufactured in a charged state and not designed for recharging. Recharging the battery can cause battery leakage, or in some cases, high pressure rupture. Disinfect your Prodigy® lancing device once a week.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Battery Replacement When replacing the battery, make sure the meter is turned off. STEP 1: With the meter off, press the buckle on the battery cover and lift up to open the cover. STEP 2: Remove the old battery and replace with new one. Be sure to align the battery properly. STEP 3: Close the battery cover. If the meter does not power on after you have replaced the battery, check that the battery is correctly installed.
PRODIGY Pocket® Blood Glucose Meter Message PRODIGY Pocket® Blood Glucose Meter Error Message What it means “HI” appears when your result is above the measurement limit, which is higher than 600 mg/dL (33.3 mmol/L). You should immediately consult your healthcare professional. Error Message Description What it means: Appears when the battery cannot provide enough power for a test. Description What it means: Appears when the temperature is out of the system operating range (50°F–104° or 10°C–40°C).
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Troubleshooting Guide v The meter does not display a message after inserting a test strip Probable Cause Actions Battery exhausted. Replace the battery. Battery incorrectly installed or absent. Check that the battery is correctly installed. Test strip inserted upside down or incompletely. Insert the test strip correctly with the bar end entering into the test strip port first. Defective meter.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter v The control solution test is out of range. Probable Cause v The control solution test is out of range. Actions Probable Cause Error in performing the test. Read the instructions thoroughly and repeat the test again. Control solution bottle not shaken well. Shake the control solution bottle vigorously and repeat the test again. Expired or contaminated control solution.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Information About your Prodigy® Meter Comparing Meter and Laboratory Results The test results you obtain from your meter may differ somewhat from your laboratory results due to normal variation. Meter results can be affected by factors and conditions that do not affect laboratory results in the same way (see test strip package insert for typical accuracy and precision data as well as important information on limitations).
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter References: 1Surwit, R.S., and Feinglos, M.N.: Diabetes Forecast (1988), April, 49-51. 2 Sacks, D.B:“Carbohydrates.” Burtis,C.A, and Ashwood,E.R.(ed.),Tietz Textbook of Clinical Chemistry. Philadelphia:W.B. Saunders Company (1994),959. Performance Characteristics • Accuracy: ±15 mg/dL when glucose <75 mg/dL ±20% when glucose >75 mg/dL • Precision: This study shows the CV (correlation variation) is less than 5%.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Unexpected Test Results Unexpected test results can occur. When this happens, please refer to these cautions. Low Blood Glucose Test Results False low results may occur if you are severely dehydrated. If you think you are severely dehydrated, contact your healthcare professional immediately. If your test result is lower than 70 mg/ dL or “Lo” appears on your meter screen, this could be a result of hypoglycemia.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Accuracy of Meter Measurements FAQ: Can two (2) blood glucose meters produce different readings that are from the same blood sample? Does this make one reading more accurate than the other? Answer: Yes, different meters can produce different readings using the same blood sample. No, this does not necessarily mean that one result is more accurate than the other. The reasons for this are as follows: 1.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Symbols Information If meter A produces a measurement of 60 mg/dL and meter B measures 80 mg/dL, then both are in the acceptable range and meet the accuracy requirement. Symbol Referent Do not re-use. Single use only. Each manufacturer has met the System Accuracy requirement as part of its testing to be cleared for marketing.
PRODIGY Pocket® Blood Glucose Meter PRODIGY Pocket® Blood Glucose Meter Warranty Information Limited Lifetime Warranty Prodigy Diabetes Care, LLC extends a limited lifetime warranty to consumers who purchase a new Prodigy® brand meter. Under this limited lifetime warranty, your new meter is covered from the original date of purchase, as long as it has not been modified, altered, or misused.
Sistema para monitoreo de glucosa Manual del propietario Manual del propietario 1
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Estimado propietario del medidor Prodigy Pocket : ® Gracias por elegir el medidor Prodigy Pocket® como su sistema para monitoreo de glucosa. Lea este manual detenidamente, ya que contiene información importante sobre su nuevo sistema Prodigy®. El sistema incluye una tarjeta de registro para la garantía. Devuélvanos la tarjeta completada o complétela en línea en www.prodigymeter.com.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Uso de la memoria del medidor................................. 44-46 Especificaciones.................................................................. 47 Visualización de los resultados en una computadora personal....................................................... 48 Cuidado del medidor Prodigy®................................... 49-52 Limpieza del sistema.......................................................
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Instrucciones importantes de seguridad Lea esto antes de usar el medidor Prodigy . Deben tomarse siempre las siguientes precauciones básicas de seguridad. ® • El medidor Prodigy®, las tiras de prueba, las lancetas y el dispositivo de punción son para el uso de un solo paciente únicamente. No los comparta con ninguna persona, ni siquiera con otros familiares. No los use en varios pacientes.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® “CDC Clinical Reminder: Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting Blood-borne Pathogens” (2010) http://cdc.gov/ injectionsafety/Fingerstick-DevicesBGM.html NO MODIFIQUE SU TRATAMIENTO EN FUNCIÓN DE UN SOLO RESULTADO QUE NO CORRESPONDA CON LA FORMA EN QUE SE SIENTE, O SI CONSIDERA QUE EL RESULTADO DE LA MEDICIÓN PODRÍA SER INCORRECTO.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Los resultados de medición inferiores a 60 mg/dl (3,3 mmol/l) indican un nivel bajo de glucosa sanguínea (hipoglucemia). Los resultados de medición superiores a 240 mg/dl (13,3 mmol/l) indican un nivel elevado de glucosa sanguínea (hiperglucemia).
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® ¿Cuándo debe usarse la AST? La comida, los medicamentos, las enfermedades, el estrés y el ejercicio físico pueden afectar los niveles de glucosa sanguínea. La sangre capilar en la yema de los dedos refleja estos cambios con mayor rapidez que la sangre capilar en otros lugares.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Consulte la sección “Realización de una medición de la glucosa sanguínea” para ver las instrucciones completas. Acerca de las tiras de prueba de Prodigy® Funciones principales de la tira de prueba Todos los medidores Prodigy® miden la cantidad de azúcar en la sangre, comúnmente denominada glucosa sanguínea.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® • Aplique solo una muestra de sangre o una muestra de la solución de control al canal absorbente de la tira de prueba. Si se aplican otras sustancias al canal absorbente de la tira de prueba, se obtendrán resultados inexactos. • Anote la fecha de eliminación en la etiqueta del frasco después de abrirlo. Deseche las tiras de prueba restantes 90 días después de la fecha en que abrió el frasco por primera vez.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® de control de Prodigy se diseñaron y probaron para funcionar como un sistema, con el fin de generar resultados exactos de mediciones de la glucosa sanguínea. ® Importante: Use solo soluciones de control y tiras de prueba de Prodigy® con el medidor Prodigy®. Si se usan otras tiras de prueba y soluciones de control con este medidor, se pueden generar resultados inexactos.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Pantalla del medidor Configuración del medidor Prodigy Pocket® Funciones principales del medidor Ranura de la tira de prueba Inserte la tira de prueba aquí. El medidor se encenderá automáticamente. Área de resultados de medición Muestra los resultados Hora Fecha de la medición. Pantalla LCD Lo guía a través de la medición mediante símbolos y mensajes simples.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Pantalla del medidor Símbolo de temperatura Aparece cuando la temperatura está fuera del rango de funcionamiento. Símbolo de pila baja Aparece cuando la carga de la pila es baja. PASO 1: Insertar la pila Abra la tapa de la pila ubicada en la parte posterior del medidor. Inserte una (1) pila de litio CR2032 de 3 voltios. El medidor debe emitir un sonido, encenderse y entrar en el modo de ajustes.
Medidor de glucosa sanguínea PRODIGY Pocket® Con el año correcto en la pantalla, (consulte la figura 9), presione el botón “SET” y la fecha aparecerá en la pantalla con el segmento del mes intermitente. Consulte la figura 10. PASO 4: Configurar el mes Presione el botón “M” y suéltelo para adelantar el mes. Con el mes correcto en la pantalla, presione el botón “SET” y el segmento de la fecha comenzará a parpadear. Consulte la figura 11.
Medidor de glucosa sanguínea PRODIGY Pocket® PASO 8: Unidad de medida Mantenga presionado el botón “M” durante hasta que la unidad de medida que desea seleccionar aparezca en la pantalla. Consulte las figuras 14 y 15. Medidor de glucosa sanguínea PRODIGY Pocket® La imagen “- - -” aparecerá en la pantalla LCD, lo que indica que se borró toda la memoria. La configuración está completa. Aparece “OFF” y el medidor se apaga. Consulte la figura 17.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Medición con solución de control Si su solución de control de Prodigy® no vino con un encarte para la solución de control de Prodigy®, la siguiente información se proporciona en lugar del encarte.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® • Cuando comience a usar un frasco nuevo de tiras de prueba. • Cuando las tiras de prueba hayan estado expuestas a condiciones ambientales extremas. • Si se le cae el medidor. • Si le cambia la pila al medidor. Almacenamiento y manipulación: • Almacene la solución de control bien cerrada a temperaturas inferiores a 30 °C (86 °F). • No la refrigere. No la guarde en el automóvil.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Importante: Asegúrese de estar en el modo de Precaución: Para evitar contaminar la solución de control con el contenido de la tira de prueba, NO APLIQUE DIRECTAMENTE LA SOLUCIÓN DE CONTROL EN LA TIRA DE PRUEBA. Consulte las figuras 19 y 20. solución de control, de modo que el resultado de la medición no se almacene en la memoria del medidor. PASO 4: Aplicar solución de control 1.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Resultados cuestionables: Si el resultado no está dentro del rango impreso en el frasco de las tiras de prueba, consulte la “Guía de solución de problemas” que se encuentra en la sección “Solución de problemas en el sistema” de este manual y repita la medición.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® hasta que el número se alinee con la flecha. Elija entre las siguientes profundidades: 1-2 (la menor penetración) para piel suave, 3 (penetración promedio) para piel normal, 4-5 (la penetración más profunda) para piel gruesa o callosa. Consulte la figura 25. Realización de una medición de la glucosa sanguínea Preparación del dispositivo de punción PASO 1: Gire la tapa del dispositivo de punción para quitarla.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® *El dispositivo de punción está preparado y listo para punzarle el dedo para obtener una muestra de sangre. Toma de una muestra de sangre PASO 1: Lavarse las manos y el sitio de punción Use agua con jabón tibia. Enjuáguese y séquese bien las manos. PASO 2: Seleccionar un sitio y punzarlo • Yema del dedo Mantenga el dispositivo de punción con firmeza contra el costado del dedo. Presione el botón de liberación.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Advertencia: La primera gota de sangre suele contener líquido tisular y suero, que pueden afectar el resultado de la medición. Se la debe descartar. Aplicación de sangre en la tira PASO 1: Insertar la tira de prueba Inserte una tira de prueba. El extremo de la barra de contacto debe ingresar a la ranura de medición primero. Empuje la tira de prueba lo más posible sin doblarla. El medidor se enciende automáticamente.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Deberá usar una tira de prueba nueva. Si tiene dificultades para llenar la tira de prueba, comuníquese con el Servicio de atención al cliente al 1.800.243.2636 para solicitar ayuda. Precaución: NO: • corra ni frote la sangre en la tira de prueba; • aplique sangre en la tira de prueba cuando la tira de prueba esté fuera del medidor; • coloque sangre ni objetos extraños en el puerto de la tira de prueba.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Uso de la memoria del medidor El Prodigy Pocket® almacena los resultados de las 120 mediciones de glucosa sanguínea más recientes con la fecha y la hora en su memoria. Además, le proporciona promedios de 7, 14 y 28 días de los resultados de las mediciones de la glucosa sanguínea. Para ver los resultados de mediciones individuales o promedio, ingrese al modo de memoria.
Medidor de glucosa sanguínea PRODIGY Pocket® Cada vez que presione y suelte el botón “M”, el medidor recuperará los resultados de hasta las últimas 120 mediciones en orden. Consulte la figura 38. Cuando la memoria esté llena, se eliminará el resultado más antiguo y se agregará el más reciente. Después de llegar al último grupo de resultados, presione el botón “M” y el medidor se apagará. Consulte la figura 39.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Visualización de los resultados en una computadora personal Cuidado del medidor Prodigy® Limpieza del sistema Limpie el medidor Prodigy® siempre que tenga suciedad visible. Para esto, limpie la parte externa del medidor con un paño humedecido con detergente suave mezclado con agua o alcohol isopropílico al 70 % (para frotar). No use lejía ni otros productos abrasivos fuertes para limpiar el medidor.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Pila El medidor Prodigy Pocket® viene con una (1) pila de litio CR2032. Las pilas se fabrican en un estado cargado y no están diseñadas para recargarlas. Si se recarga la pila, esta puede tener pérdidas, o en algunos casos, se puede romper a alta presión. Desinfecte el dispositivo de punción de Prodigy una vez por semana.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Cambio de la pila Cuando cambie la pila, asegúrese de que el medidor esté apagado. Solución de problemas en el sistema PASO 1: Con el medidor apagado, presione la presilla en la tapa de la pila y levántela para abrir la tapa. PASO 2: Retire la pila vieja y cámbiela con una nueva. Asegúrese de alinear la pila correctamente. PASO 3: Cierre la tapa de la pila.
Medidor de glucosa sanguínea PRODIGY Pocket® Mensaje Medidor de glucosa sanguínea PRODIGY Pocket® Error Mensaje Su significado “HI” aparece cuando el resultado está por encima del límite de medición, que es mayor a 600 mg/dl (33,3 mmol/l). Debe consultar inmediatamente a su profesional de la salud. Error Mensaje Descripción Su significado: aparece cuando la pila no tiene suficiente carga para una medición. Acción: cambie la pila inmediatamente.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Guía de solución de problemas v La medición no se inicia después de aplicar la muestra. v El medidor no muestra un mensaje después de insertar la tira de prueba. Causa probable Acciones La pila está agotada. Cambie la pila. La pila está mal instalada o no está. Verifique que la pila esté correctamente instalada. La tira de prueba se insertó al revés o no se insertó completamente.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® v La medición con la solución de control está fuera del rango. v La medición con la solución de control está fuera del rango. Causa probable Acciones Error en la realización Lea detenidamente las de la medición. instrucciones y repita la medición. Agite la botella de la solución La botella de la solución de control no de control enérgicamente y repita la medición. se agitó bien.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Información sobre el medidor Prodigy® Comparación de los resultados del medidor y un análisis de laboratorio Los resultados de medición que obtiene del medidor pueden diferir un poco con los resultados de un análisis de laboratorio, debido a la variación normal.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Referencias: Surwit, R.S., and Feinglos, M.N.: Diabetes Forecast (1988), April, 49-51. 2Sacks, D.B: “Carbohydrates.” Burtis, C.A, and Ashwood, E.R. (ed.), TietzTextbook of Clinical Chemistry. Philadelphia: W.B. Saunders Company (1994),959.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Resultados no esperados de la medición Las mediciones pueden arrojar resultados no esperados. Cuando esto ocurra, remítase a estas precauciones. Resultados de glucosa sanguínea baja en la medición Se pueden obtener resultados bajos falsos si está gravemente deshidratado. Si piensa que está gravemente deshidratado, comuníquese con su profesional de la salud de inmediato.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® 2.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® se consideran exactas si están dentro de ±15 mg/dl de 70 mg/dl (de 55 mg/dl a 85 mg/dl). Información sobre símbolos Si el medidor A arroja una medición de 60 mg/dl y el medidor B arroja una medición de 80 mg/dl, ambas están en el rango aceptable y cumplen con el requisito de exactitud.
Medidor de glucosa sanguínea PRODIGY Pocket® Medidor de glucosa sanguínea PRODIGY Pocket® Información sobre la garantía Garantía limitada de por vida Prodigy Diabetes Care, LLC ofrece una garantía limitada de por vida a los consumidores que compren un medidor nuevo de la marca Prodigy®. Conforme con esta garantía limitada de por vida, su nuevo medidor está cubierto desde la fecha de compra original, siempre que no se lo haya modificado, alterado ni usado indebidamente.