Product Specs
Table Of Contents
- 1. Introduction
- 2. Features
- 3. Functional description
- 4. External interfaces
- 5. Mechanical
- 6. Environmental
Confidential
SPD RFID Reader 2021-09-23
SPD6873160007R07.docx Page 18 of 20
Pulse
Severity
Half sine
30 G, 11ms
Table 6-6: PSD for random vibration
Frequency (Hz)
PSD (g2/Hz)
5
0.015
10
0.5562
15
0.1799
20
0.0763
50
0.0179
75
0.0095
90
0.0237
150
0.1549
200
0.0078
300
0.0064
400
0.0128
500
0.0042
600
0.0177
700
0.0331
800
0.0500
900
0.0126
1000
0.0003
Table 6-7: Non-operational mechanical test
Standard
Description
Parameters
Remarks
ISO 16750-3 3th
editon 2012
Drop test
Non-operational
Height
1.0m
6.4. Ingress Protection
Table 6-8: Ingress protection test
Standard
Description
Parameters
Remarks
ISO 20653
IP rating from all directions
Non-operational
IP69K
6.5. UV / Chemical / Salt spray
5
Table 6-9: Non-operational mechanical test requirements
Standard
Description
Parameters
Remarks
ISO4892
UV test
Non-operational
500 hours
dE < 3
EN 60068-2-52
Salt spray
Non-operational
Severity 5
-
Chemical test (brush test)
Non-operational
Engine oil
Diesel fuel
Antifreeze/water solution
Brake fluid
6.6. EMC
6.6.1. Emission
Table 6-10: Emission standards
Standard
Description
Remark
EN 12895
Industrial trucks EMC
6.6.2. Immunity
10
Table 6-11: Immunity standards
Standard
Description
Limits
Remark
ETSI EN 301 489-1
V2.2.3
General requirement
Vehicular use equipment