User manual
5.1. SUSPENDING AX3210P AND AX1118SP SYSTEMS 5. Guide to System Setup
Figure 5.8: Caster boards are disengaged and stacked.
• The array is lifted off the ground
In this phase the array has to be eased in its natural movement by holding the handles on the last
enclosure of the array to avoid a sharp forward shifting toward the natural ver tical centre provided
by the lifting point. We advise operating on the vertical lifting point as much as possible in order to
keep the array from shifting forward.
During the lifting phase, and particularly when there is only one caster board left on the ground, do
not stop the ascent, or you will damage the only caster board supporting the weight of the whole
array.
11. Caster boards are disengaged
50