5. Guide to System Setup 5.3. SUSPENDING AX2265P AND AX1115SP SYSTEMS
During the lifting phase check continuously to make sure that the space between each
loudspeaker and the next is free and that the lifting is smooth. If jams were to occur or
if cables were to enter the space between the enclosures, do not try to free them
during compression or lifting. Never try to operate in the space between the
loudspeakers while they are being hoisted.
Once the first loudspeakers of the array are under compression you can disengage the slotted bar
from its frame and insert it in the frame of the next loudspeaker.
6. Slotted bars are inserted in the frame
At this point you can set the relative angle between the enclosures by inserting the pins through
the numbered holes on the frame or in the slotted bar itself. To couple the bar you can either use
the hole at its end or the slot. If you use the slot the relative angle are print in the side plate.
7. The angles are set by inserting the pins
• Lifting proceeds
Once the angle of the first enclosures has been set, you can continue lifting the array, putting
another section under compression and proceeding iteratively, setting the angle of the subsequent
enclosure one by one using the corresponding hole in the frame.
67