MANUALE UTENTE – USER’S MANUAL DIMMER 1K PLDM1K Rev.
INDICE CARATTERISTICHE GENERALI ............................................ 4 CARATTERISTICHE TECNICHE ............................................ 5 ISTRUZIONI GENERALI ...................................................... 5 UTILIZZO SICURO ED EFFICIENTE ................................... 5 AVVERTENZE ........................................................................ 6 CONTROLLO E FUNZIONI ..................................................... 7 PANNELLO FRONTALE ..................................
TABLE OF CONTENTS GENERAL FEATURES ......................................................... 12 TECHNICAL SPECIFICATIONS............................................ 13 GENERAL INSTRUCTIONS............................................... 13 SAFE AND EFFICIENT USE .............................................. 13 PRODUCT CARE ................................................................. 14 CONTROLS AND FUNCTIONS ............................................ 15 FRONT PANEL ..................................
CARATTERISTICHE GENERALI Grazie per l’acquisto del dimmer PLDM1K. Questo modello è un modulo dimmer ad un canale. Possiede una varietà di funzioni che includono: • Porta DMX IN / OUT standard a 3 poli per fornire informazioni sul dimmer; • Modalità SWITCH PACK o DIMMER PACK; • Assegnazione DMX, Dimmer Preset e Dimmer Limit; • Memoria in caso di mancanza di alimentazione; • Display per la visualizzazione dell’attività in corso e lo stato della funzione.
CARATTERISTICHE TECNICHE Input di alimentazione AC 230V ~ 50Hz Output canale 6 A max Ingresso / uscita DMX Prese XLR a 3 poli Fusibile F6.3 A 250V 5×20 mm Dimensioni (mm) 182×92×65 Peso (kg) 1,1 ISTRUZIONI GENERALI Leggere attentamente le istruzioni contenute in questo manuale prima di installare od utilizzare il prodotto. Successivamente, conservare il manuale in un luogo sicuro allo scopo di poterlo consultare in futuro.
• Per prevenire rischi di incendio o di shock elettrico, non esporre il prodotto alla pioggia o all’umidità. • Evitare di eseguire la riparazione. Eventuali interventi da parte di personale non qualificato ne provocherebbe danni o il funzionamento difettoso. AVVERTENZE • Questo prodotto è destinato all’esclusivo utilizzo interno. • Provvedere a non precludere la ventilazione durante l’utilizzo. • Disconnettere la presa di alimentazione quando l’unità non viene utilizzata per lunghi periodi.
CONTROLLO E FUNZIONI PANNELLO FRONTALE 1. Uscita: 6 A max. 2. Display: Mostra l’attività in corso o lo stato della funzione. 3. Pulsante MENU: Premere per entrare al livello successivo. 4. Pulsante UP: Ogni pressione aumenterà il valore di una unità. 5. Pulsante DOWN: Ogni pressione diminuirà il valore di un’unità. Premendolo e mantenendo premuto lo diminuirà rapidamente.
PANNELLO POSTERIORE 1. Cavo di alimentazione: Connettere all’appropriata presa di corrente. 2. Fusibile: F6.3 A 250V 5×20 mm 3. Ingresso DMX: Presa XLR maschio a 3 pin per ricevere dati DMX 4. Uscita DMX: Presa XLR femmina a 3 pin per inviare dati DMX GUIDA AL FUNZIONAMENTO Connettere all’appropriata presa di corrente.
Il prodotto funziona da dimmer pack o switch pack a seconda della modalità operativa selezionata. Assicurarsi che i requisiti di alimentazione corrispondano a quelli specificati su questa unità. MODALITÀ DMX ADDRESS 1. Il Display mostra l’indirizzo DMX dell’ultima A 12 3 modifica effettuata. Se l’ultima volta era stato selezionato l’indirizzo DMX 123, il display visualizzerà 123. 2. Ogni pressione del pulsante UP o DOWN A 125 cambierà l’indirizzo Premendolo e DMX di mantenendolo una unità.
S -on 3. Premere il pulsante MENU per entrare in modalità Switch Pack. La modalità Switch Pack consiste di Switch On (S-on) e Switch Off (S-of). In modalità Switch On, l’output è attivo e l’apparecchio si illuminerà indipendentemente al segnale DMX. I modalità Switch Off, l’output è inattivo e l’apparecchio è controllato dal segnale DMX. Quando il livello DMX è inferiore al 40% l’apparecchio si spegne; quando il livello DMX è superiore al 40% l’apparecchio si illumina 4.
L 8 8 8 3. Premere il pulsante MENU per entrare in modalità Dimmer Limit. 4. Premere il pulsante UP o DOWN per L 8 8 8 cambiare il valore entro la gamma si 10100. Ogni pressione cambierà il valore di una unità. Premendo e mantenendo premuto il pulsante, il valore cambierà rapidamente. P 8 8 8 5. Premere il pulsante menu per entrare in modalità Dimmer Preset. 6. Premere il pulsante UP o DOWN per P 8 8 8 cambiare il valore entro la gamma di 00100. Ogni pressione cambierà il valore di una unità.
GENERAL FEATURES Thank you for your purchase. This product features include: • 3 pin standard DMX IN / OUT ports providing dimmer information. • Serves as a Switch Pack or Dimmer Pack, depending upon the current operation mode. • Allows DMX Addressing, Dimmer Preset and Dimmer Limit. • Power failure memory. • Display shows current activity and function state. Every effort has been made to design dependability, reliability and comfort into each unit.
TECHNICAL SPECIFICATIONS Power Input AC 230V ~ 50Hz Channel Output 6 A max DMX In / Out 3 pin XLR socket Fuse F6.3 A 250V 5×20 mm Dimensions (mm) 182×92×65 Weight (kg) 1,1 GENERAL INSTRUCTIONS Please read through this operating instructions before installing or using your new product. After you have finished reading this guide, put it in a safe place for future reference.
PRODUCT CARE • This product is intended for indoor use only. • Provide occasional ventilation during use. • Unplug the power plug from the sockets when not using the unit for extended period. • Do not use the unit in places subject to excessive humidity, vibration or bumps. • Place this unit in a stable location. • Do not dismantle or modify the unit.
CONTROLS AND FUNCTIONS FRONT PANEL 1. Output: 6 A max 6. Display: Shows current activity or function state. 7. MENU button: Press to enter next level. 8. UP button: Each tapping will increase the value once. Pressing and holding down will increase quickly. 9. DOWN button: Each tap will decrease the value once. Pressing and holding down will decrease quickly.
REAR PANEL 1. Power Cord: Plug in the appropriate power outlet. 2. Fuse: F6.3 A 250V 5×20 mm 3. DMX Input: 3 pin XLR socket used to receive DMX data 4. DMX Output: 3 pin XLR socket used to send DMX data OPERATION GUIDE Plug in the appropriate power outlet , this unit recovers to the function state of last time automatically by reasons of power failure memory and the display shows the DMX address of last change.
DMX ADDRESS MODE 1. The display shows the DMX address of last A 12 3 change when powered this unit. If you’ve selected DMX address 123 for the last time, then the display will show 123. 2. Each tap ph the UP or DOWN button will A 125 change the DMX address once. Pressing and holding down will change the DMX address quickly. Once the DMX address is selected, it will be stored into memory automatically. Note: during DMX addressing, output is disable. SWITCH PACK MODE 1.
In the Switch Off mode, output is turned off and the fixture is controlled by DMX signal. When DMX level is less than 40% the fixture goes out. When DMX level exceeds 40% the fixture lights. S -of 4. Tap the UP or DOWN button to change between Switch On and Switch Off. 5. Once the Switch Pack is selected, press A 12 5 MENU button to return to DMX Address mode. DIMMER PACK MODE 1. Press MENU button to enter next level. A 12 5 d - - - 2.
4. Tap the UP or DOWN button to change L 8 8 8 the value within the range of 10-100. Each tap will change the value once, pressing and holding down will change the value quickly. Once the Dimmer Limit is selected, it will be stored automatically. P 8 8 8 5. Press MENU button to enter Dimmer Preset mode. 6. Tap the UP or DOWN button to change P 8 8 8 the value within the range of 00-100. Each tap will change the value once, pressing and holding down will change the value quickly.
PROEL S.p.A. (World Headquarters – Factory) Via alla Ruenia 37/43 64027 Sant’Omero (TE) – Italy Tel. +39 0861 81241 Fax. +39 0861 887862 e-mail: info@proelgroup.com www.proelgroup.