5.  Led Level indicator - Vu meter 
It indicates the output signal level . For a correct amplifier volume use, the volume level must be set 
between –20 dB e 0 dB and when the first five leds are on. If such level makes lighting only the first 2 
leds (+3 dB +6 dB), the output signal could be distorted the volume then must be reduced. 
6.  Digital Radio Module 
7.  ON/OFF Switch for Radio Section 
8.  Radio volume control 
9.  CD/MP3 player module 
10.  CD housing 
11.  USB Input 
12.  Brackets for 19” rack housing purposes” 
13.  Handle 
3.  REAR PANEL CONTROL 
fig. 2 
1.  Main Power supply plug ( with fuse) 
2.  Protection Fuse 
It protects the unit against eventual power supply voltage variation. It can be replaced . 
3.  Main power supply voltage selector 230/117Vca 50/60Hz 
4.  Inputs INPUT1 ~ INPUT4: 
a.  COMBO/XLR Input connector 
b.  Euro block terminal – can be removed 
c. Dip-switch: 
 PIN1 position ON=Input for a signal- Micro level 
 position OFF=input for a signal-.LINE level  
 PIN2 position ON = Input direction is inverted 
 PIN3 position ON = High pass filter – active in input (ideal for speech) 
 position OFF = on input no filter action 
 PIN4 position ON = Phantom 48V active 
 position OFF = Phantom 48V not active 
When INPUT1 is active , the unit makes in Mute status all other signal sources 