MANUALE UTENTE - INSTRUCTION MANUAL Preamplificatore/Mixer – Mixer Preamplifier AMIX63
INDICE 1. PRECAUZIONI D’USO ............................................................................................................................ 4 2. DESCRIZIONE .......................................................................................................................................... 6 3. FUNZIONI E CONTROLLI PANNELLO FRONTALE ........................................................................ 6 4. FUNZIONI E CONTROLLI PANNELLO POSTERIORE.........................................
1. PRECAUZIONI D’USO AVVERTENZA:Per ridurre il rischio di folgorazione, non rimuovere il coperchio (o il pannello posteriore). All’interno non sono contenute parti riparabili dall’utente; affidare la riparazione a personale qualificato. ATTENZIONE: Per ridurre il rischio d’incendio o di folgorazione, non esporre questo apparecchio alla pioggia o all’umidità.
Uso sicuro della linea d’alimentazione: • Quando si scollega l’apparato alla rete tenere saldamente sia la spina che la presa. • Quando l’unità non viene utilizzata per un periodo prolungato, interrompere l’alimentazione estraendo la spina dalla presa dell’alimentazione • Per evitare danni alla linea d’alimentazione dell’apparato, non mettere in trazione il cavo d’alimentazione e non utilizzare un cavo attorcigliato.
Grazie per aver scelto un prodotto Proel e della fiducia riposta nel nostro marchio, sinonimo di professionalità, accuratezza, elevata qualità ed affidabilità. Tutti i nostri prodotti sono conformi alle normative CE per utilizzazione continua in impianti di diffusione sonora. 2.
5. EQUALIZER Consente di regolare i toni Bassi Medi ed Alti 6. L R Indicatore dei livelli Master Left e Right 7. MASTER Consente di regolare il livello sull’uscita L, R e MONO OUT (fig.2 rif.5, 6 ) 8. ON Led di accensione 9. Alette di fissaggio rack standard 19” 4. FUNZIONI E CONTROLLI PANNELLO POSTERIORE fig.2 1. MIC/LINE INPUT Ingressi MIC/LINE 1~6 tipo COMBO (XLR female + Jack 6,3) bilanciato 2. SELETTORE Consente di selezionare il livello segnale in ingresso LINE - MICRO con PHANTOM 18V – MICRO.
6. MONO OUT Uscita MONO bilanciata (XLR male) 7. REC OUT Uscita di registrazione (RCA). Per registrare, collegare a quest’uscita un registratore 8. INGRESSO ALIMENTAZIONE DI RETE Collegare l’unità alla rete 230Vac 50/60Hz. Alloggio per fusibile da 450 mA. Nota: nella versione 117V la tensione di riferimento è 117Vac 50/60Hz 9.
Esempio 2 9
6.
7. CONTENUTO DELLA CONFEZIONE AMI63 Cavo di alimentazione Manuale utente 8. CARATTERISTICHE TECNICHE Model INPUT CH1~CH6 MIC input Gain Max. Input S/N Phantom power Line Input Frequency Response Sensitivity Electronically Balanced 0 dB to -50 dB +18dBu (line/mic) ≥85 dB 16~19 V DC Electronically Balanced 20Hz-22KHz +/-3dB 0 dBu INPUT CH7~CH9 Line Input Sensitivity Max. Input S/N Unbalanced 0 dBu +20dBu ≥105 dB Frequency Response T.H.D.
INDICE 1. IMPORTANT SAFETY INSTRUCTIONS ........................................................................................... 14 2. DESCRIPTION ........................................................................................................................................ 16 4. REAR PANEL FUNCTIONS AND CONTROLS ............................................................................... 17 5. OPERATION .........................................................................................
1. IMPORTANT SAFETY INSTRUCTIONS CAUTION: To reduce the risk of electric shock do not remove cover (or back panel). No user serviceable parts inside. Refer servicing to qualified personnel only. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Objects or liquid entry into the unit: Be careful that no objects fall into the unit or that no liquid is spilled inside the unit through ventilation openings. Safe power line use: • Hold the plug and the wall outlet firmly while disconnecting the unit from AC power. • When the unit will not be used for a long period of time, please unplug the power cord from AC power outlet. • To avoid power cable damage, don’t strain the AC power cable and don’t bundle it.
Thank you for choosing this Proel product and for trusting our brand, which strives to be synonymous with professionalism, precision, high quality and reliability. All of our products comply with EC regulations regarding audio equipment for continuous use. 2. DESCRIPTION This device was specifically designed to mix microphone and music signals for sound reinforcement systems.
5. EQUALIZER Adjusts Low, Mid and High tone 6. L R Left and Right Master level indicator 7. MASTER Adjusts levels on L, R e MONO OUT outputs (fig. 2; ref. 5, 6) 8. ON Power LED 9. Standard 19” rack fixing brackets 4. REAR PANEL FUNCTIONS AND CONTROLS fig.2 1. MIC/LINE INPUT Balanced COMBO type MIC/LINE inputs 1-6 (female XLR + 6,3 mm Jack) 2. SELECTOR Allows the selection of LINE or MIC signal level input or MIC level input with 18 V Phantom power.
6. MONO OUT Balanced MONO output (male XLR) 7. REC OUT Recording output (RCA). Connect a recorder to this output to record 8. MAINS INPUT Use the provided power cable to connect this to a 230 V AC 50/60 Hz outlet. 450 mA fuse housing. Note: for the 117V version the correct voltage is 117 V AC 50/60Hz 9. Emergency Power Supply Connectors Connect these to the emergency power supply (24 V DC) to ensure working continuity of the device in case of AC power loss 5. OPERATION a.
Example 2 19
6.
7. PACKAGE CONTENTS AMI63 Power cable Instruction Manual 8. TECHNICAL FEATURES Model INPUT CH1~CH6 MIC input Gain Max. Input S/N Phantom power Line Input Frequency Response Sensitivity Electronically Balanced 0 dB to -50 dB +18dBu (line/mic) ≥85 dB 16~19 V DC Electronically Balanced 20Hz-22KHz +/-3dB 0 dBu INPUT CH7~CH9 Line Input Sensitivity Max. Input S/N Unbalanced 0 dBu +20dBu ≥105 dB Frequency Response T.H.D.
NOTE _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ___________________________
PROEL S.p.A. (World Headquarters - Factory) Via alla Ruenia 37/43 64027 Sant’Omero (Te) – Italy Tel: +39 0861 81241 Fax: +39 0861 887862 E-mail: info@proel.com www.proel.