Name Description
ALED
B Latch Button
Bracket that secures the CANopen Master Unit to the
LT.
C Extension Connector
Connect the extension connector to the AUX unit
interface/expansion unit (EXT2) at the rear side of the
LT.
D CANopen Interface CANopen Slaves Interface
LED
Color
Status Description
PWR
Green
ON Power is on.
OFF Power is OFF.
RUN
Green
Blinks once per
second.
Communication
STOPPED state.
Blinks three
times and then
blinks again
three times after
1 second has
elapsed.
Initialization is in
progress.
ON
Normal
Communication
State.
ERR
Red
OFF
Normal
Communication
State.
Blinks once per
second.
Communication
data error
Blinks twice and
then blinks again
twice after 1
second has
elapsed
Check the node ID
and baud rates of
the connection
devices.
ON
The connected
device is not
connected to the
bus. (BUS OFF)
Blinking
The node ID
address or
communication
settings are invalid.