User guide

GP3000 Series Hardware Manual
5-4
Output Specifications (Sink type)
Output Circuit (Sink type)
Rated Voltage DC 24V
Rated Voltage Range DC 20.4V to DC 28.8V
Output Method Sink Output
Maximum Load Voltage 0.2A /point, 0.4A /common
Output Voltage Drop 1.5V or less
Output Delay Time
OFF to ON: 1ms or less
ON to OFF: 1 ms or less
Voltage Leakage (when OFF) 0.1mA or less
Clamp Voltage 39V ±1V
Type of Output Transistor Output
Common Lines 1
Common Design 2 points/1 common line
External Connection 12-pin connector (also used for Input)
Output Protection Type Output is unprotected
Internal Fuse 1.5A, 125V DIP fuse (not replaceable)
Surge Control Circuit Zener diode
Output Points 2
Output Signal Display No LED indicators
Status Display Element None
Isolation Method Photocoupler Isolation
External Power Supply DC 24V
Since the output terminals are not electrically protected, an output line might be short-circuited
or a connection fault might damage the GP unit. Please install an applicable fuse to prevent an
overload in the circuit, if necessary.
L
L
+24V B1
OUT1 A2
0V A1
OUT0 B2
Internal Circuit
Internal Circuit
Fuse 1.5A
DC 24V
External Power
+
-