Manual

21
Contact Rating
240 VAC, 2 A (resistance load, cos ø=0.4 induced
load)
30 VDC, 2 A (resistance load, L/R-7 ms induced
load)
Output Delay Time
Initial Shorting Resistance 30 m max. 45 m max.
Electrical Life
100,000 operations or more
(rated resistive load 1,800 operations/h)
Mechanical Life
20 million operations or more
(no load 18,000 operations/h)
Voltage Endurance
Between output to terminals: 1500 VAC, 1 minute
Between output terminal and internal circuit: 1500
VAC, 1 minute
Between output groups: 1500 VAC, 1 minute
External Connection
11-pin terminal
connector
Terminal Block
(nonremoval)
*1 Operating Range
EXM-DMM8DRT EXM-DMM24DRF
Command
Output
Relay
Status
OFF delay:
10 ms max.
Contact bounce:
6 ms max.
ON delay: 6 ms max.
ON
OFF
ON
OFF
Input Voltage (VDC)
28.8
24
15
5
0
01.2 4.2 78.4
ON Area
Transition Area
OFF Area
Input Current (mA)
Input Impedance