16
(2) Selected Associated Nonincendive Field Wiring Apparatus shall satisfy the following:
(3) If the electrical parameters of the cable are unknown, the following values may be used:
Capacitance = 60pF/ft, Inductive = 0.20 µH/ft
(4) Nonincendive Field Wiring must be installed in accordance with article 501.10(B) of the National Elec-
trical Code ANSI/NFPA 70.
(5) Nonincendive Field Wiring Apparatus shall not contain or be connected to another source of power.
CE Marking
The FP3650-T41 and FP3710-T41-U, FP3710-T41, FP3710-T42-U, FP3710-T42, FP3900-T41-U, FP3900-T41 are CE
marked products complying with both the EMC Directive and low-voltage directive.
The FP3500-T41-24V and FP3600-T41-24V are CE marked products complying with the EMC Directive.
Each complies with the following standards.
*For detailed CE marking information, contact your local FP distributor.
Nonincendive Field
Wiring Apparatus
- Front module of FP unit
Vo c ≤ Vmax
Isc ≤ Imax
Ca ≥ Ci+C cable
La ≥ Li+L cable
Type Standards for EMC directive Standard for Low Voltage directive
FP3500-T41-24V
FP3600-T41-24V
EN55011 Class A and EN61000-6-2
-
FP3650-T41
EN60950-1 First Edition
FP3710-T41-U
FP3710-T41
FP3710-T42-U
FP3710-T42
FP3900-T41-U
FP3900-T41