FP-2500/FP-2600 Series User Manual
7-3
7.2 Periodic Check Points
The gasket must be inserted correctly into the groove for the FP unit’s
moisture resistance to be equivalent to IP65f.
Be sure the gasket's seam is not inserted into any of the unit's cor-
ners, only in the straight sections of the groove. Inserting it into a
corner may lead to its eventually tearing.
The upper surface of the gasket should protrude approximately 2mm
out from the groove. Be sure to check that the gasket is correctly in-
serted before installing the FP into a panel.
To keep your FP unit in its best condition, please inspect the following points periodi-
cally.
FP Operation Environment
Is the ambient temperature within the allowable range (0
o
C to 50
o
C )?
Is the ambient humidity within the specified range (30%RH to 90%RH, dry
bulb temperature of 39
o
C or less)?
Is the operating atmosphere free of corrosive gasses?
Electrical Specifications
Is the Rated Voltage Range appropriate ?
Related Items
Are all power cords and cables connected properly? Have any become loose?
Are all installation fasteners holding the unit securely?
Are there any scratches or traces of dirt on the installation gasket?
7.2 Periodic Check Points
unit: mm [in.]
2.0 [0.08]
FP Model Number Rated Voltage Range
FP2500-T12
FP2600-T12
AC85 to 264V
FP2500-T42-24V
FP2600-T42-24V
DC19.2 to 28.8V