Operation Manual

HALOGEN HAND LAMP BASIC
EN - 1
PLI-128
We thank you for the purchase of this Profile
product. Note: It is important that you read this
manual carefully before using the product and
be sure to save this manual for possible use
later.
Note
Check if building regulations apply to your area
whereby you must have the halogen hand
lamp installed by an accredited electrician. An
electrician can give you information about
correct wiring. Never install the fitting outside in
rainy weather.
SWITCH OFF THE POWER BEFORE YOU
INSTALL THE HALOGEN HAND LAMP.
Correct installation
With installation outside preferably choose a
place under a roof.
Connect the halogen hand lamp to a circuit
with wall switch.
The following distances must be respected
with installation:
Fig. 1 Fig. 2
Unscrew the stainless steel bolts on the side
to take the holder from the fitting.
Fix the holder to the wall with 2 screws. Do
not fix the holder to a highly flammable
surface. Leave a distance of at least 1 m
between the halogen hand lamp and the
object to be illuminated. (See fig.2) Install the
halogen hand lamp at least 2.5 m above the
ground. (see fig.1)
Fix the halogen hand lamp back on the
assembled holder.
Fig. 3
Remove the cover of the cable connection.
Pull the power supply wires through the
opening with the rubber packing.
Connect the electric wiring according to
figures 3 and 4.
The halogen hand lamp must be connected
to mains voltage of 230V, max. fusing 16A.
Screw the cable connection cover tight
again.
Always respect the instructions on the
identification label of the connected power
cables.
Other uses than described above can cause
damage to the product and increase the risk
of short-circuit, fire, electric shocks, etc.
The product may not be adapted as a whole.
The safety instructions must be strictly
observed.
Safety instructions
The importer accepts no responsibility for
damage claims with respect to objects or
persons that result from incorrect use or non-
compliance with the safety instructions. Any
damage claims in such cases will be
declared null and void.
When replacing the halogen bulb the lamp
must first have cooled before the bulb is
replaced. Also disconnect the power supply.
Do not exceed the maximum wattage of
500W.
Always replace cracked or broken glass by
glass with the same properties as the original
glass.
Technical information
Working voltage: 230V AC (50/60 Hz)
Maximum lamp power: 500W
Maximum current strength: 10/16A
Dustproof and splashproof: IP44.
Fig. 4
*
L = phase
* = earthing
* N = neutral

Summary of content (2 pages)