® Owner’s Operation & Installation Guide FLUSHMATE A Division of Sloan Valve Company PF1612PA
A Division of Sloan Valve Company PF1612PA and Owner’s Operation and for Installation Guide for 503 and 504 Series PF1612PA Series Guía de instalación y operación del propietario para las series PF1612PA 503 y 504 Guide d’installationetet Guide d’installation de fonctionnement fonctionnementdes des séries 503 et 504 séries PF1612PA Important: Do not return to store where purchased. Please read the entire manual before attempting to make any adjustments or repairs.
Operation All pressure-assist pressure-assisttoilets toiletsget gettheir theirenergy energyfrom fromthethewater water supply line. supply line. It isIt is important to have sufficient pressure at supply. the supply. minimum important to have sufficient pressure at the The The minimum line line pressure is 25 psi gpf for 1.0 gpf.is 20 psi and 25 psi for 1.0 gpf. pressure for a 1.6 system Fig. 1 Step 1.Check CheckFlush Flush Cartridge Step 1. Cartridge A. Turn off water water supply and flflush toilet.
Operación Todos los los excusados excusadosasistidos asistidospor porpresión presiónobtienen obtienensusuenergía energía tubería de dede la la tubería suministro de de agua. EsEs importante ciente en de suministro agua. importantetener tenerpresión presiónsufi suficiente enelelsuministro. La presión mínima de mínima la tubería agua para un sistema 25 psi de para un suministro. La presión de de la tubería de agua para undesistema dispositivo de20 1.0psi gpf. 1.
Fonctionnement Toutes les toilettes à pression pression tirent tirent leur leur énergie énergie du du tuyau tuyaud’alimentation. d’alimentation. Il est donc important d’avoir samment de d’avoir suffi suffisamment de pression pression d’alimentation. d’alimentation.La La pression du tuyau d’alimentation pour moins psi pour 1 pour un un système système àà d’au 1,6 gpc doit25être gpc. d’au moins 20 psi, et d’au moins 25 psi pour 1 gpc. Fig. 1 Étape Vérification la cartouche de chasse Étape 1.1.
Installation Instalación Installation Please follow the toilet manufacturer’s installations instruction for installing the fixture. Note that the toilet requires a minimum water supply line pressure of 25 psi for a 1 gpf fixture. Before attaching, you should always flush the water supply lines. Siga las instrucciones de instalación del fabricante del excusado para instalarlo.
Winterizing Preparación para el invierno Préparation pour l’hiver 1. Turn off the water supply valve and flush the toilet to relieve the pressure. 2. Place a bucket under the lower Supply Shank (A) and disconnect the water supply line, allowing the water to drain into the bucket. 3. Push down on the Actuator and pull it up momentarily to allow air into the vessel. 4. Follow the fixture manufacturer’s instructions for winterizing the bowl. 5.
® Tank Service Manual FLUSHMATE Flushometer - Tank System 504 PF1612PA
FLUSHMATE® 503 AND 504 SERIES q static water pressure* p PF1612 Series FLUSHMATE® 504 Function: Less than 1.0 gpf/3.8 Lpf Installation Requirements: min. 25 psi static water pressure* *max. 125 psi (F) (H) 1. Lower Supply Group w/Hose BL100504-3 (A) Supply Shank (B) Pressure Regulator w/Back Check (C) Relief Valve ❸ 2. Upper Supply Group BU100505 (D) Air Inducer (E) Vacuum Breaker ❹ (B) List of Components for 503 andSeries 504 Series: PF1612 (C) ❷ ❶ (I) (E) (A) (G) (D) 3.
PLEASE READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO MAKE ANY ADJUSTMENTS OR REPAIRS. WARNING: • When replacing components on the FLUSHMATE® Flushometer-Tank System, make certain that the water supply valve is turned off and the toilet has been flushed to relieve pressure in the FLUSHMATE® tank.
c. Examine the exposed O-rings on the Flush Valve Cartridge for obstruction or damage. If the O-rings are damaged, the Flush Valve Cartridge should be replaced. Clean any debris from the O-ring before re-installing. (See Figure 4) Figure 6 d. Insert the Flush Valve Cartridge into the FLUSHMATE® tank and thread it clockwise into place until one (1) black thread (on the FLUSHMATE® tank) is showing above the Flush Valve Cartridge.
Condition: Vacuum Breaker Leaking If the Vacuum Breaker (E) is leaking, it is likely that the water pressure is insufficient or that there is insufficient flow due to a plugged inlet screen in the lower Supply Shank. The recommended static pressure for the 503 Series is between 20 psi and 125 psi and for the 504 Series between 25 and 125 psi.
ATTENTION OWNER THESE ARE THE TERMS OF YOUR WARRANTY Effective August 15, 2004, Sloan FLUSHMATE® (the “Company”) warrants the FLUSHMATE® (flushometer tank) operating system (the “unit”) to be free of defects in material and workmanship for a period of ten (10) years from the date of installation on original components and includes a lifetime limited warranty on the FLUSHMATE® tank.