Installation Guide

NOTICE Height and/or piping restriction will reduce the pump output performance.
Whenever possible use the same or larger size pipe than the pump discharge for optimum
performance. Reducing the pipe size will not harm your pump; it will just slow the flow.
PERFORMANCES
SPECIFICATIONS
Power supply requirements 120V, 60 Hz
Motor Continuous Duty***, Capacitor Start
Amps 7.6
Horsepower ½ HP
Liquid Temperature Range 32° F - 120° F
Circuit Requirements 15 amp
Discharge Size 2”
Solids Handling 2”
***For continuous duty, the pump must be submerged to prevent overheating.
DANGER Do not use this unit to pump flammable or corrosive liquids. You could injure
yourself and the pump will fail. Pumping these types of liquids voids the warranty. Make sure
you purchase a pump designed for your specific needs.
WARNING
Your pump has thermal over-load protection built in. It is not recommended for pumping
liquids over 120 F. The thermal overload protector will automatically shut down the pump in
an overheat situation. It will then reset itself once the pump cools down and the pump will
work again. The overload protector is designed as a safety device and it will fail after
repeated use. Normal operation is for fluids between 40 F & 120 F. DO NOT RUN THE
PUMP DRY. The pump depends on water for cooling and lubrication. Operating the pump
without water may cause the motor to overheat or cause damage to parts of the pump. It may
also shorten the life of your pump.
NOTICE
EXTENSION CORDS
For best performance, it is recommended to connect the power cord directly to the grounded
GFCI outlet. If the use of an extension cord is necessary, always use a grounded waterproof
type cord. Never use longer than a 25-ft. cord that is lighter than 14/3 gauge.
DANGER Keep all electrical connections away from wet and moist environments. Wet
connections can cause electrical shock resulting in serious or fatal injury.
USE AND INSTALLATION
Your PROFLO Pump is designed and built to give you reliable performance and long life. It
will pump automatically for years when properly installed in the right environment.
WARNING ALWAYS DISCONNECT THE POWER SOURCE BEFORE ATTEMPTING TO INSTALL,
SERVICE OR PERFORM MAINTENANCE ON THE PUMP. FAILURE TO DO SO MAY RESULT IN FATAL
ELECTRICAL SHOCK.
REMOVING OLD PUMP. (If necessary)
1. Make sure power supply is disconnected.
2. After the power is off, remove the old pump. There are many different possible types of
installations.
3. It is best to remove all old piping and start over with new piping.
Be sure to have a grounded 120V AC outlet mounted within 6 ft. of your basin. Again, it is
highly recommended that a ground fault interrupter outlet (GFCI) be installed in the receptacle
box.
Discharge Height above pumping level
0’
5’
10’
15’
20’
25’
GPM
80
68
60
44
25
2
GPH
4800
4080
3600
2640
1500
300
6 3