Instruction manual

PLEASE NOTE! The energy output is determined by the energy dials A and B. The energy out-
put will remain consistent, regardless of which lamp sockets are used or the number of lamp
heads connected to them. Energy dumping is not necessary as long as the dial MASTER is
turned to MAX.
Energy Control
The generator’s total energy is regulated with the control MASTER (6). The total energy can be
adjusted in 1/6 f:stop increments from MAX down to minus 8/6 f:stops equivalent to 1 1/3
f:stops. When reducing the energy a flash has to be released with the white push-button [11]. Then
the chosen energy is obtained. Please also see ”Manual Bracketing” (page 20), ”Autobracket-
ing” (page 20) and ”Colour Temperature” (page 23).
Choice of Modelling Light
The control [15] MOD. LIGHT is used to choose the following alternatives:
• OFF Modelling light off
• 1/1 Modelling light is receiving the designated proportional full energy determined by the
positions of dials A, B & MASTER
1/2 Modelling light is receiving the designated proportional half energy determined by
the positions of dials A, B & MASTER
• MAX Modelling light is at maximum, regardless of energy settings
Half proportional modelling light is chosen when a Pro-7a/1200 and a Pro-7a/2400 are used
together. To keep the modelling light proportionally aligned between the two generators, the
Pro-7a/1200 is set to a 1/2 modelling light position, as the flash energy is half of the
Pro-7a/2400.
18
[4] [6] [9]