model no. EH-4604BY GARAGE HEATER with Remote IMPORTANT: Please read this manual carefully before running this garage heater and save it for reference.
model no.
Technical Specifications 4 Important Instructions 5 General Safety Information 6 Locating Heater 7 Installation Instructions 8 Operating Instructions 12 Cleaning and Maintenance 14 NOTE: If any parts are missing or damaged, or if you have any questions, please call our toll-free helpline at 1-866-206-0888. SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions. Read all instructions and follow them with use of this product.
model no. EH-4604BY | contact us 1-866-206-0888 DESCRIPTION TECHNICAL SPECIFICATIONS Model Number EH-4604BY Voltage 240 V Rated Power 5,000 W / 7,500 W AMPS 20.9 / 31.3 1250W Element 1250W Element Overheat 1250W Element 1250W Element 1250W Element AC 240V / 60Hz 1250W Element Terminal station TGP-085 Power light TECHNICAL SPECIFICATIONS Electric utility heaters are designed to meet a variety of heating requirements by switching a few wires located in the base of the unit.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read all instructions before installing or using this heater. 2. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3' (0.
model no. EH-4604BY | contact us 1-866-206-0888 GENERAL SAFETY INFORMATION GENERAL SAFETY INFORMATION 1. 2. 3. 4. 5. 6. 7. 8. 9. Use only copper wires rated for at least 75ºC. Heater airflow must be directed parallel to or away from adjacent wall. Observe wall, floor and ceiling clearance requirements. All wiring must be done according to applicable national and local electrical codes in the United States and Canada. The heater must be grounded as a precaution against possible electric shock.
LOCATING HEATER 14" (35.6 cm) MINIMUM DISTANCE TO WALL 13" (33 cm) MINIMUM DISTANCE TO WALL 10 5/8" (26.9 cm) 4 1/2" (11.4 cm) 4 1/2" (11.4 cm) 7 3/8" (18.7 cm) MINIMUM DISTANCE FROM DISCHARGE TO ANY OBJECT 12 1/2" (31.8 cm) 1 3/4" (4.4 cm) Note: Minimum clearance to ceiling when not using mounting brackets is 1 5/8" (4.1 cm). 36" (91.4 cm) 1/2" (12.7 mm), 3/4" (19.1 mm) MINIMUM DISTANCE TO FLOOR 8' (2.4 m) MAXIMIUM MOUNTING HEIGHT FROM: Vertical air delivery unit = 11' (3.
model no. EH-4604BY | contact us 1-866-206-0888 INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HARDWARE NEEDED You will need the following hardware, which can be purchased from your local hardware store or electrical supply house: • Adequate gauge and length of wire for your application. • Proper size fuse or breaker to handle amperage. • Proper wire connectors for your application. • Fasteners appropriate for application that are strong enough to hold the unit.
1. To turn the unit when it has been installed with a single lag bolt (as shown in Figure 3a), simply turn the entire heater as needed. The unit cannot be turned horizontally if it has been installed with 2 lag bolts. 2. To tilt the unit vertically, loosen the bracket screws (see Figure 4). 3. Adjust louvers to the desired position. NOTE: To prevent possible overheating, please maintain adequate clearance as shown in Figure 5.
model no.
The heater includes a fan delay function to prevent risk of overheating. When turning the heater off, the unit will close the heating element first and then the fan will continue working for 60 seconds to dissipate residual heat. 1. Remove the screw from the front of the unit to connect the power to the heater. 2. Attach the cable connectors to the unit (see Figure 8) and slide the 8-gauge wire through the cable connector.
model no. EH-4604BY | contact us 1-866-206-0888 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1 2 3 4 5 6 Figure 10 1 2 3 4 5 6 Timer Up Down ºF / ºC Heating (off/fan/low/high) Power INSTRUCTIONS IN NORMAL MODE Power button You can use the power button as the On/Off switch. The Power button can also be used to lock settings. Select desired heating settings with HEATING and UP/DOWN buttons, then press Power button for 10 seconds. All settings will be locked and cannot be changed.
REMOTE CONTROL 1 2 3 4 5 6 Power (on/off) ºC/ºF display Up Heating (off, fan, low, high) Down Timer 1 2 4 C/ F º º 5 3 Once the room temperature reaches the set point, the heater will automatically stop running. The LED will display the current room temperature for 5 seconds after each operation. 6 Figure 11 NOTE: This remote requires a 3V lithium battery (included). THERMAL CUT-OUT The heater will automatically turn off when parts of it overheat, and the red indicator will be illuminated.
model no. EH-4604BY | contact us 1-866-206-0888 CLEANING AND MAINTENANCE CLEANING AND MAINTENANCE 1. Before cleaning, make sure the power has been turned off at the main breaker panel and that the heating element of the heater is cool. 2. To maintain the external appearance of the heater, it need only be wiped occasionally with a dry duster. During the summer months, or at other times when the appliance is not in use and is completely cold, wipe exterior surfaces with a damp cloth.