Ceiling Fan Installation Manual P2514
PROGRESS LIGHTING 30-YEAR LIMITED WARRANTY PROGRESS LIGHTING FAN MOTORS ARE WARRANTED TO THE END USER TO BE FREE OF ELECTRICAL AND/OR MECHANICAL DEFECTS FOR A PERIOD OF 30 (THIRTY) YEARS FROM DATE OF SALE. PULL CHAIN SWITCHES, REVERSE SWITCHES, CAPACITORS AND METAL FINISHES ARE WARRANTED FOR A PERIOD OF 1 YEAR. WARPING OF WOODEN OR PLASTIC BLADES IS NOT COVERED BY THIS WARRANTY. THE END USER HAS THE OPTION OF RETURNING THE DEFECTIVE FAN TO THE PLACE OF PURCHASE DURING THE FIRST 30 DAYS FOR A REPLACEMENT.
Safety Rules..................................................................................................................................... 1. Unpacking Your Fan ......................................................................................................................... 2. Installing Your Fan ........................................................................................................................... 3. Installing the Light Kit................................................
To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 9. 2. All wiring must be in accordance with the National Electrical Code and local electrical codes. Electrical installation should be performed by a qualified licensed electrician. 10. Do not use water or detergents when cleaning the fan or fan blades.
2 8 11 1 a 9 3 b 6 12 7 4 . 10 13 Unpack your fan and check the contents. You should have the following items; 1. 2. 3. 4. 5. 6. Fan blades (3) Canopy assembly Ball/downrod assembly Coupling cover Fan motor assembly Mounting plate 7. 8. 9. 10. 11. 12. Light plate Glass shade 10 0 Watt halogen bulb 13. Loose parts bag containing: Receiver with 6 wire nuts a. Blade attachment hardware (10 screws, 10 fiber washers ) Transmitter incl. 2 mounting screws Balancing kit b.
Tools Required Figures 1,2 and 3 are examples of different ways to mount the outlet box. Phillips screw driver, straight slot screw driver, adjustable wrench, step ladder, and wire cutters. Provide strong support Recessed outlet box Mounting Options If there isn't an existing UL listed mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers. Secure the outlet box directly to the building structure.
Hanging the Fan REMEMBER to turn off the power. Follow the steps below to hang your fan properly: Step 1. Remove the decorative canopy bottom cover from the canopy by turning the cover counter clockwise.(Fig. 5) Step 2. Remove the mounting bracket from the canopy by removing the 1 of 2 screws from the bottom of the mounting bracket and loosening the other one a half turn from the screw head. Next, turn the canopy counter clockwise to removing the mounting bracket from the canopy. (Fig, 5) Step 3.
Make the Electric Connections WARNING: To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: This remote control unit is equipped with 16 code combinations to prevent possible interference from or to other remote units. The frequency switches on your receiver and transmitter have been preset at the factory.
BLACK WHITE BLACK SUPPLY CIRCUIT Ground Conductor Step 1. Tuck connections neatly into ceiling outlet box. Outlet Box Step 2. Slide the canopy up to mounting bracket and place the key hole on the canopy over the screw on the mounting bracket, turn canopy until it locks in place at the narrow section of the key holes. (Fig. 11) BLUE BLACK WHITE BLUE BLACK WHITE GREEN ON WHITE Finishing the Installation Green Ground Lead Ground to Downrod Step 3.
Attaching the Fan Blades Insert the blade through the slot in housing. Align holes in blade and motor and secure with 3 screws and fiber washers. Repeat process with the other blades. (Fig. 12) Blade Balancing All blades are grouped by weight. Because natural woods very in density, the fan may wobble even though the blades are weighed equally. WARNING TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE BLADE HOLDERS WHILE INSTALLING, BALANCING THE BLADES, OR CLEANING THE FAN.
Installing the Mounting Plate REMEMBER: To disconnect the power. The fan blades must be already attached to the fan. Step 1. Remove 1 of the 3 screws from the mounting ring and loosen the other 2 screws. (Do not remove) Step 1. Remove the 3 screws from the mounting plate and keep it for future use. Step 2. Place the key holes on the mounting plate over the 2 screws previously loosened from the mounting ring, turn mounting plate until it locks in place at the narrow section of the key holes.
Installing the battery: Install 12V MN21/A23 battery (included), to prevent damage to transmitter, remove the battery if not used for long periods. Bulb Connection plugs Mounting plate Light plate Screws Glass shade Figure 15 9.
" button (inside the battery Restore power to ceiling fan and test for 4. The " compartment in the back side of the proper operation. 1. " , , " buttons: These three buttons are used to set the fan speed as follows: = Low speed = Medium speed = High speed 2. " " button: This button turns the fan off. 3. The " " button turns the light ON or OFF and also controls the brightness setting. Press and release the button to turn the light ON or OFF. Press and hold the button to set the desired brightness.
Here are some suggestions to help you maintain your fan 1.Because of the fan's natural movement, some connections may become loose. Check the support connections, brackets, and blade attachments twice a year. Make sure they are secure. (It is not necessary to remove fan from ceiling.) 2. Clean your fan periodically to help maintain its new appearance over the years. Use only a soft brush or lint-free cloth to avoid scratching the finish.
Problem Solution Fan will not start. 1.Check circuit fuses or breakers. 2. Check line wire connections to the fan and switch wire connections in the switch housing. CAUTION: Make sure main power is off. 3. Check to make sure the dip switches from the transmitter and receiver are set to the same frequency. Fan sounds noisy. 1. Make sure all motor housing screws are snug. 2. Make sure the screws that attach the fan blade bracket to the motor hub is tight. 3.
Fan Size 52" Speed Volts Amps Watts RPM CFM Low 120 0.35 14 74 1911 Medium 120 0.47 35 123 2679 High 120 0.52 51 160 3613 These are approximate measures. They do not include Amps and Wattage used by the light kit. C 2005 Progress Lighting Co. 101 Corporate Dr., Spartanburg, SC 29304-5704 All Rights Reserved 13. Specifications N.W. G.W. C.F. 16.17 lbs 19.8 lbs 1.
GARANTÍA LIMITADA DE 30 AÑOS LOS VENTILADORES PROGRESS LIGHTING GARANTIZAN AL CONSUMIDOR ESTAR LIBRES DE DEFECTOS ELÉCTRICOS Y/O MECÁNICOS POR UN PERÍODO DE 30 AÑOS A PARTIR DE LA FECHA DE VENTA. LOS INTERRUPTORES CON CADENA, LOS INTERRUPTORES DE INVERSIÓN, LOS CONDENSADORES Y LAS TERMINACIONES METÁLICAS ESTÁN GARANTIZADAS POR UN PERÍODO DE 1 AÑO. LAS PALETAS PANDEADAS DE MADERA O PLÁSTICO NO ESTÁN CUBIERTAS POR ESTA GARANTÍA.
Normas de seguridad ...................................................................................................................................................................... 1. Cómo desembalar el ventilador ...................................................................................................................................................... 2. Cómo instalar el ventilador ..............................................................................................................
1. Para reducir el riesgo de eléctrocución, asegurarse de que la eléctricidad se ha desactivado en el cortacircuitos o caja de fusibles antes de comenzar. 2. Todo cableado debe relizarse conforme al Código Electrico Nacional y los códigos electricos locales. La instalación eléctrica debe ser relazada por un eléctricista registrado calificado. 3.
5 2 8 11 1 a 9 3 b 6 12 7 4 10 13 Desembalar el ventilador y revisar el contenido. Debe tener los siguientes elementos: 1. 2. 3. 4. 5. 6. Juego de aspas (3) Escudete superior Conjunto de bola/tubo de suspensión Cubridor del motor Conjunto de motor del ventilador. Plato de montaje 7. 8. 9. 10. 11. 12. Plato de luz Pantalla de luz Bombilla de Halogeno de 100W Receptor + 6 tuercas de cable Transmisor + soporte + 2 tornillos de montaje Juego de balanceo 13. Dos bolsas de piezas pequeñas: a.
Herramienta necesarias Angulo máximo en el techo: 24° Destornillador Phillips, destornillador normal, llave de tuercas ajustable, escalera de tijera, y cortadoras de alambre. Opciones de instalación Caja de distribución embutida Si no hay una caja con UL registración de montaje existente, sirvase leer las siguientes instrucciones. Desconectar el suministro de electricidad removiendo los fusibles o desactivando los cortacircuitos.
Colocación del ventilador RECUERDE desconectar la alimentación. Siga estos pasos para colocar correctamente el ventilador: Paso 1. Retire la tapa embellecedora del fondo del cobertor girando la tapa en sentido de las agujas del reloj. (Fig. 5) Paso 2. Quite el soprte de montaje de la cubierta quitando 1 de los 2 tornillos de la parte inferior del soprte de montaje y aflojando el otro media vuelta desde la cabeza del tornillo.
Realice las Conexiones Electricas AVISO: Para evitar posibles descargas eléctricas, asegurese de que la eléctricidad esta antes de realizar el cableado. NOTA: Está unidad con control a distancia está equipada con 16 combinaciones de códigos diferentes para evitar posibles interferencias de otras unidades a distancia. Los interruptores de frecuencia del receptor y del transmisor están preestablecidos desde fabrica.
NEGRO BLANCO NEGRO CIRCUITO DE ALIMENTACIÓN Conductor a tierra AZUL BLANCO NEGRO BLANCO AZUL NEGRO BLANCO VERDE Caja de distribución Hilo de tierra, verde Conexion a tierra para la barra descendente Paso 1. Meta las conexiónes en forma ordenada adentro de la toma de corriente. Paso 2.
Instalacion de las Aspas Meta la aspa por la ranura del ensamblaje del motor, alinie los agujeros de la aspa y el motor y asegure la aspa con tres tornillos prooveidos. Repita el proceso con las otras aspas. (Fig. 12) Balanceo de las Aspas Todas las aspas están agrupadas por peso. Debido a que la desidad de las maderas naturales varía, el ventilador podría oscilar aún cuando el peso de las aspas esté equilibrado. El siguiente proceimiento deberia mayor parte de la oscilación del ventilador.
Instalación de la Placa de Montaje Paso 1. Quite 1 de los 3 tornillos del anillo de montaje y afloje los otros 2 tornillos. (No los quite) Paso 2. Coloque los agujeros del plato de montaje en los 2 tornillos previamente aflojados del anillo de montaje, gire el plato de montaje hasta que quede fijo en su lugar en la parte estrecha de los agujeros. Asegúrela apretando los 2 tornillos aflojados y también el que quitó anteriormente. (Fig.
Instalación de la Bateria Coloque 12V MN21/A23 bateria (incluidas). Para evitar estropeos del transmisor, extreiga la bateria cuando esté no se usa por periodo relativamente largo. Bombilla Conectores Plato de montaje Plato de lampara Tornillos Difusor de vidrio Figura 15 9.
Conecte la eléctricidad a el ventilador y confirme que opera debidamente. 1. Los bottones , , : Estos tres botones son usados para seleccionar las velocidades del ventilador de la manera siguiente: = Velocidad Alta = Velocidad Mediana = Velocidad Baja 2. Boton" ": Esté boton apaga el ventilador. 3. El boton " " es para prender y apagar la luz, tambien se usa para controlar la intensidad de la luz. Apriete y sostenga el boton hasta obtener la intensidad de luz deseada.
He aqui algunas sugerencias para ayudarle el 3. Se puede aplicar una capa ligera de pulidor para muebles a las aspas de madera para brindar mantenimiento del ventilodor. protección adicional y realzar su belleza. Cubrir los rayones pequeños con una ligera aplicación de 1. Debido al movimiento natural del ventilador, betún para calzado. algunas conexiones se podrian aflojar. Examinar las conexiones del soporte, soportes, y accessorios de las aspas dos veces al año. Asgurarse de que estén 4.
Problema Solución El ventilador no arranca. 1. Revisar los fusibles o interruptores de circuitos. 2. Verificar las conexiones de cables de linea al ventilador y conexiones de cable del interruptor. PRECAUCIÓN : Asegurarse de que la fuente pricipal de electricidad esté desactivada. 3. Revise los interruptores de frequencia del receptor y transmisor, los interruptores de las dos unidades debén de estar en las mismas posiciones.
Tamaño del Ventilador 52" (132 cm) Velocidad Voltios Amperios Vatios RPM CFM Baja 120 0.35 14 74 1911 Mediana 120 0.47 35 123 2679 Alta 120 0.52 51 160 3613 Estas son mediciones aproximadas. No incluyen los Amperios y vatios usado por el juego de iliminación. c 2005 Progress Lighting Co. 101 Corporate DR., Spartanburg, SC 29304-5704 All Rights Reserved 13. Especificaciones N.W. 16.17 lbs G.W. 19.8 lbs 1.