Dimensions Guide

Test conducted under stabilized laboratory conditions following published industry standards. Various operating factors can cause differences
between laboratory data and actual field measurements.
REPORT NUMBER: 2,949 PAGE: 1 OF 6
ISSUE DATE: 1/11/2012 8:10:17 AM
PREPARED FOR: HUBBELL
LUMINAIRE: Progress P8071-Record-1009L
LAMP: Energy Star Fixture Job #2489028
X:-0.30 Y:2.25
26.9 deg C
0.950
23:20.8 Stable
0.00 %
0.46 %
1.0000 - 1.0078
691.44
CANDELA DISTRIBUTION FLUX
0.0 90.0 180.0 270.0
0 434 434 434 434
5 429 429 429 429 41
15 398 399 398 397 112
25 339 341 343 339 156
35 250 255 257 252 158
45 162 165 167 163 126
55 72 70 72 71 67
65 24 22 23 22 23
75 6 6 6 6 6
85 3 2 3 2 3
90 1 1 0 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 309 44.6
0- 40 467 67.5
0- 60 659 95.3
0- 90 691 100.0
90-180 0 0.0
0-180 691 100.0
CIE TYPE - DIRECT
PLANE : 0-DEG 90-DEG 180-DEG
SPACING CRITERIA : 1.1 1.1 1.1
PLANE : 0-DEG 90-DEG
LUMINOUS LENGTH : 6.000 6.000
LUMINANCE DATA IN CANDELA/SQ M
ANGLE AVERAGE AVERAGE AVERAGE
IN DEG 0-DEG 90-DEG 180-DEG
45 9861. 10039. 10148.
55 5408. 5260. 5421.
65 2398. 2235. 2354.
75 1036. 955. 1019.
85 1486. 1215. 1319.
LEGEND:
0-deg:
90-deg:
180-deg:
270-deg:
Approved
Checked
150
300
450
15˚ 30˚
45˚
60˚
75˚
90˚
ELECTRICAL DATA P8071-28/30K-L10-STR2
Input Voltage 120V
Input Frequency 43-63 Hz
Input Current 0.10A
Input Power 12W
Constant Current Output 700mA
Power Factor >0.90
THD <20%
EMI Filtering FCC 47CFR
Part 15, Class B
Operating Temperature -30ºC to 60ºC
Dimming Yes*
Over-voltage, over-current, short-circuit protected
*See Dimming Notes for more information
ZONAL LUMEN SUMMARY
ZONE LUMENS %LUMINAIRE
0-30 433 44%
0-40 654 66%
0-60 937 95.2%
0-90 684 100%
P8071-28/30K-L10-STR2
LED Light Engine: 3000K 83 CRI
System Wattage: 12
Fixture delivered lumens: 1038
Fixture Efficacy: 87.0
Spacing Criteria: 1.1
CANDELA
DISTRIBUTION
DEG CANDELA
0 634
5 630
15 588
25 504
35 384
45 257
55 129
65 41
75 8
85 3
90 0
Test No. CSA 2585298
Tested at 25ºC Ambient in accordance to IESNA LM-79-2008
Tested in P87-AT housing
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method
% Effective Ceiling Cavity Reflectance
80% 70% 50% 30%
20% Effective Floor Cavity Reflectance
% Wall Reflectance
70 50 30 10 70 10 50 10 50 10
1 112 108 105 102 109 103 102 97 98 94
3 97 89 82 77 95 81 84 75 82 74
5 84 73 66 60 82 65 70 59 68 59
7 73 62 54 49 72 54 60 48 58 48
9 65 53 46 41 63 45 51 40 50 40
Room Cavity
Ratio
P8071-28/30K-L10-STR2
Test No. CSA 2585298
Single Unit, Initial Footcandles, 30" Work Plane Ceiling
to Floor
Height (ft)
Multiple Units, Initial Footcandles, 30" Work Plane
Nadir 10º 20º 30º Spacing is Maximum Over Work Plane, SMH = 1.1
FC FC Dia (ft) FC Dia (ft) FC Dia (ft) Fixture Spacing (ft) RCR 2 RCR 5 RCR 7
52 48 1 37 3 24 4 6 4.0 69 51 43
21 19 2 15 4 10 6 8 6.0 28 21 18
10 9 3 7 6 5 9 10.5 9.0 13 10 8
7 6 3 5 7 3 11 12 10.0 9 7 6
PERFORMANCE DATACHART
220
440
660
90º
75º
60º
45º
15º 30º