Specification Sheet

For more information visit our website: www.progresslighting.com
Progress Lighting • 701 Millennium Boulevard • Greenville, SC 29607
P8108 SERIES
.5 Inch LED New Construction And Remodel • Wet location listed
P8108-28-30K
Photometrics:
ELECTRICAL DATA P8108-28-30K
Input Voltage 120 V
Input Frequency 60 Hz
Input Current 0.104 A
Power Factor >0.90
THD <20%
EMI Filtering FCC Title 47, Part 15 Class B
Operating Temperature -30 °C to 30º C
Dimming Yes*
Over-voltage, over-current, short-circuit protected
*See Dimming Notes for more information
P8108-28-30K
LED Light Engine: K, CRI
System Wattage: .
Fixture Delivered Lumens:
Fixture Efficacy: .
Spacing Criteria: .
ZONAL LUMEN SUMMARY
Zone Zone_Lumens %_Luminaire
0-30 250 33.2
0-40 394 52.2
0-60 637 84.5
0-90 754 100.0
90-180 0 0.0
0-180 754 100.0
CANDELA DISTRIBUTION
DEGREE CANDELA LUMENS
0 341
5 338 32
15 318 89
25 280 129
35 229 143
45 174 134
55 122 109
65 75 75
75 35 37
85 3 5
90 0