(P8240-20/30K9-AC1-L06) Specification Sheet
P8240 Series
LED New Construction and Remodel • Wet Location
Photometrics:
P8240-28/30K9-AC1-L06
ELECTRICAL DATA P8240-28/30K9-AC1-L06
Input Voltage 120V AC
Input Frequency 50/60 Hz
Input Current 0.11A
Input Power 12.7W
Power Factor >0.90
THD <20%
EMI Filtering FCC 47CFR
Part 15, Class B
Operating Temperature -30ºC to 40ºC
Dimming Yes*
Over-voltage, over-current, short-circuit protected
*See Dimming Notes for more information
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
REPORT NUMBER: 7,976 PAGE: 1 OF 5
ISSUE DATE: 4/24/2015 11:26:07 AM
PREPARED FOR: PRESCOLITE
LUMINAIRE: LBS5LEDA6L30K9 WH
24.7 deg C
0.9282
40.11%
0.11440
120.02
36:33.3 Stable
DEG CANDELA LUMENS
0 234
5 232 22
15 222 63
25 203 93
35 177 111
45 146 112
55 111 100
65 75 74
75 38 40
85 6 8
90 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 178 28.6
0- 40 289 46.3
0- 60 501 80.4
0- 90 623 100.0
90-180 0 0.0
0-180 623 100.0
TOTAL INPUT WATTS = 12.74
EFFICACY = 48.9 Lm/W
CIE TYPE - DIRECT
LUMINAIRE SPACING CRITERION = 1.2
LUMINOUS DIAMETER: 3.500
LUMINANCE DATA IN CANDELA/SQ METER
ANGLE AVERAGE
IN DEG
45 33252.
55 31166.
65 28580.
75 23645.
85 11087.
80
160
240
0˚ 15˚ 30˚
45˚
60˚
75˚
90˚
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0-30 178 28.6
0-40 289 46.3
0-60 501 80.4
0-90 623 100.0
P8240-28/30K9-AC1-L06
LED Light Engine: 3000K, 92 CRI
System Wattage: 12.7
Fixture delivered lumens: 623
Fixture Efficacy: 48.9
Spacing Criteria: 1.2
CANDELA DISTRIBUTION
DEG CANDELA
0 234
5 232
15 222
25 203
35 177
45 146
45 111
55 75
65 38
75 6
90 0
90º
75º
60º
45º
80
160
240
0º 15º 30º
Test No. 15.00666 70030959
Tested at 25º Ambient in accordance to IESNA LM-79-2008
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method
% Effective Ceiling Cavity Reflectance
80% 70% 50% 30%
20% Effective Floor Cavity Reflectance
% Wall Reflectance
70 50 30 10 70 10 50 30 50 30
1 109 104 100 97 106 95 98 95 94 92
3 91 80 72 66 88 65 76 69 73 67
5 76 64 55 48 74 48 60 53 58 52
7 66 52 43 37 64 37 50 42 48 42
9 57 44 36 30 56 30 42 35 41 34
Room Cavity
Ratio
P8240-28/30K9-AC1-L06
Test No. 15.00666 70030959
Ceiling to Floor
Nadir Height (ft)
FC FC Dia (ft) FC Dia (ft) FC Dia (ft) Fixture Spacing (ft) RCR 2 RCR 5 RCR 7
19 18 1 14 3 10 4 6 4.0
8 726446 8 7.0
4 333629 10.5 10.0
3 232 7 1 11 12 11.0
6
Spacing is Maximum Over Work Plane, SMH= 1.2
7
4
20
o
1823
9
30
o
13
Single Unit, Initial Footcandles, 30" Work Plane
2
4
32
34
Multiple Units, Initial Footcandles, 30" Work Plane
10
o