Installation Guide

WARNING: When using Special Control Devices with this fixture, follow instructions carefully to assure NEC
compliance. For more help, contact a Qualified Electrical Contractor.
WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects and/or other
reproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this product.
CAUTION: To complete the installation, choose only UL Listed Progress Trims from the label inside the Housing. The
use of any trim not listed in this Fixture is a Violation of NEC Article 110-3 (B) and Voids All Warranties.
1. For I.C. APPLICATIONS where the Fixture may be in direct Contact with the insulation, remove the Peel-Off Warning
Label (1) from the Housing (3) that reads: "WARNING RISK OF FIRE, DO NOT INSTALL INSULATION WITHIN 3
INCHES OF THE SIDES OF THE HOUSING".
2. FOR NON-I.C. APPLICATIONS where, except for mounting points, the Fixture is installed at least 1/2 inch from any
combustible surface and Insulation is a minimum of 3 Inches from all sides, Remove Peel-Off I.C. Wattage Label (2)
from inside the Housing (3).
3. For Wooden Joists: Use the Centering Notches (4) located on the Plaster Frame to position the Fixture. Extend the
Bar Hangers (6), use joist alignment tabs to locate fixture and hammer the 4 Nails (7) into Joists (8). Drive additional
nails through holes in Bar Hanger for alternate support if required. Bars may be shortened at score mark to fit tight
mounting conditions and joist alignment tabs removed to adjust vertically as needed by breaking off with pliers.
4. On Suspended Ceilings: Place the Fixture on the ceiling grid with the "T" Bars (9) running through the Bar Hanger
Notches (10). Using a flat head screwdriver or other tool, bend the integral t-bar mounting tabs (11) downward to a
vertical position (Fig. 3). Secure housing to the support structure with tie wire (supplied by others) in the holes supplied.
Sheetmetal screws (supplied by others) can also be used in the holes supplied (20).
5. Locate Housing along Bar Hanger in desired position and, using pliers, squeeze the 4 Locking Tabs (12) on the
Plaster Frame (13) tightly over the Bar Hangers to prevent further Housing movement. Bar Hangers (6) may be installed
in alternate Slots (23) if mounting conditions require.
6. Unsnap Junction Box Cover (14) by lifting the Leaf Spring.
7. Run supply wires through UL Listed connectors (not supplied) in one of the five Pryouts (15) on the Junction Box (16)
or Type NM cable (ROMEX) through an Opening above the Wire Retaining Plate (17). Connect Supply Wires (19) as
shown in Fig 4 & 5. Replace Cover.
8. FOR AIR-TIGHT APPLICATIONS, such as Washington State Energy Code Requirements, the Progress housing
is compliant with ASTME283 restricted air flow regulations. Always follow local building codes to ensure compliance.
9. Loosen Screws (21) to adjust Housing (3) for variations in ceiling thickness. Bottom of Housing should be flush with
ceiling (22) within tolerance. Slot Covers (18) can be rotated 180 degrees in thick ceiling applications to maintain
Air-Tight requirements, "V" should be facing outward.
10. Select a Trim from the Wattage Label inside the Housing. Use Only Lamp Types approved for the Trim chosen. DO
NOT EXCEED MAXIMUM LISTED WATTAGE(S)! Follow instructions with Trim to complete installation.
(Ceiling Opening is to be 6-7/8" Dia.)
Remove Socket Paint Cap prior to installing Trim and Lamp
****************************************************************************************************************************************************************************************************
P87-ATQC
Follow this instruction sheet carefully. Be sure electricity is OFF before starting installation.
Assembly & Installation Instructions
Read instructions carefully and turn electricity off at main
circuit breaker panel before beginning installation.
CAUTION:
(06/23/14) REV. DSPEC.NO. 93010189
PAGE 1 of 4