Specification

Photometrics:
P Medium LED Track Head
Track mounted • Dry location listed
PK
ELECTRICAL DATA P--K
Input Voltage  V
Input Frequency  Hz
Input Current . A
Input Power .
Power Factor >.
THD <%
EMI Filtering FCC Title , Part  Class B
Operating Temperature - °C to º C
Dimming Yes*
Over-voltage, over-current, short-circuit protected
*See Dimming Notes for more information
701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION,
APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
REPORT NUMBER: 17.01929 PAGE: 4 OF 8
ISSUE DATE: 07/18/17
PREPARED FOR: PROGRESS
CATALOG NUMBER: P90612827K9
DEG CANDELA LUMENS
0 1263
5 1173 99
15 397 118
25 190 89
35 148 85
45 18 21
55 9 8
65 5 5
75 3 3
85 0 0
90 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 306 71.4
0- 40 391 91.2
0- 60 420 98.0
0- 90 428 100.0
90-180 0 0.0
0-180 428 100.0
EFFICACY = 63.7 lm/W
CIE TYPE - DIRECT
LUMINAIRE SPACING CRITERION = 0.40
PLANE : 0-DEG 90-DEG
SHIELDING ANGLES : 90 90
LUMINOUS DIAMETER: 2.250
LUMINANCE DATA IN CANDELA/SQ M
ANGLE AVERAGE
IN DEG
45 9924.
55 6117.
65 4612.
75 4519.
85 0.
450
900
1350
15˚ 30˚
45˚
60˚
75˚
90˚
P--K
LED Light Engine:  K + CRI
System Wattage: .
Fixture delivered lumens: 
Fixture Efficacy: .
Spacing Criteria: .
ZONAL LUMEN SUMMARY
Zone Lumens %Fixt
0-30 306 71.4
0-40 391 91.2
0-60 420 98.0
0-90 428 100.0
90-180 0 0.0
0-180 428 100.0
CANDELA DISTRIBUTION
DEG CANDELA LUMENS
 
 
  
  
  
  
 
 
  
 
 