(P9204-28) Specification Sheet

Progress Lighting
701 Millennium Blvd.
Greenville, South Carolina
29607
www.progresslighting.com
BR30 and PAR30 Lamp Application Data
Rev. 12/99
Horizontal Surfaces
Clg Ht. Height from floor to ceiling
F.C. Footcandles 30” from floor (work plane)
Dia. & Diameter of effective lighted area and spacing
Spacing to effectively light the horizontal surface
Walls and Vertical Objects
H
D
F.C. Footcandles at center of beam
Width of effective lighted area
Height from ceiling to center of beam
Distance from fixture to wall
Length of effective lighted area
Spacing of multiple fixtures to effectively light wall
L
W
S
Figure 1
Single lampholder
D
H
FC
L
W
Figure 2
Multiple lampholders
D
H
FC
L
S
CBCP - Center Beam Candlepower
*L is height of wall
HF.C.LWSF.C. LWSF.C.LWS F.C.
Clg.
Ht.
Dia. &
Spacing
Walls and Vertical Objects
Horizontal Surfaces
65BR30FL 2465.7 2.92.3 345.1 3.8 2.923 5.64.7 3.6 8175.1
CBCP - 525 3 22 17.3 3.8 2.9218.6 4.43.4 17 12.05.2 4.0912 6
Beam - 55 deg. 412*4.73.6 13 16.75.2 4.011 11.45.9 4.51096.9
D = 2 FT D = 3 FTD = 4 FT
BR30 Flood Lamp
65BR30SP 3 69 2.51.3 1.2642.2 1.51.4 52 2.21.8 1.7854 1.9
CBCP - 1625 4364.0 1.61.5 393.1 1.81.7 362.9 2.01.9 9382.3
Beam - 20 deg. 5216.3 1.91.8 25 4.42.1 2.0253.8 2.3 2.210292.6
D = 2 FT D = 3 FTD = 4 FT
BR30 Spot Lamp
50PAR30/HIR/FL 3 64 5.3 2.3 2.0594.2 2.72.4 48 4.23.2 2.8850 3.3
CBCP - 1500 434 10.42.8 2.5366.4 3.2 2.833 5.63.6 3.1 9363.9
Beam - 35 deg. 519 24.23.4 3.0 23 9.93.7 3.2 23 7.64.0 3.6 10 27 4.5
50PAR30FL 3 60 5.3 2.3 2.0554.2 2.72.4 45 4.23.2 2.8846 3.3
CBCP - 1400 431 10.42.8 2.5346.4 3.2 2.8315.6 3.6 3.1 9333.9
Beam - 35 deg. 518 24.23.4 3.0 21 9.93.7 3.2 21 7.64.0 3.6 10 25 4.5
75PAR30FL 3
3
85 5.82.4 2.1794.5 2.82.5 64 4.53.3 2.9866 3.5
CBCP - 2000 445 12.13.0 2.6486.9 3.3 2.9446.0 3.8 3.3 9474.1
Beam - 35 deg. 52632.3 3.6 3.1 30 11.03.9 3.4 318.3 4.3 3.7 10 364.8
75PAR30FL-L 133 3.2 1.61.5 122 2.81.9 1.8902.9 2.22.1 8 102 2.4
CBCP - 3100 4705.5 2.01.9 74 4.02.2 2.1683.7 2.52.3 9742.8
Beam - 25 deg. 5409.3 2.42.2 47 5.82.6 2.4404.9 2.82.7 10 55 3.2
D = 2 FT D = 3 FTD = 4 FT
PAR30
Flood Lamps
50PAR30/HIR/NSP 4313 1.3 0.80.8 287 1.3 0.90.9 247 1.3 1.01.0 12 144 1.5
CBCP - 13,000 61302.4 1.11.0 1392.1 1.11.1 154 1.81.2 1.216712.1
Beam - 9 deg. 863 4.01.3 1.3 73 3.2 1.41.4 77 2.81.5 1.520422.7
50PAR20NSP 4 166 1.50.9 0.9 152 1.41.0 1.01311.4 1.11.1 10 123 1.3
CBCP - 6,900 6692.7 1.21.2 74 2.3 1.3 1.2812.0 1.3 1.3 12 76 1.7
Beam - 10 deg. 833 4.51.5 1.5393.6 1.61.5 41 3.2 1.71.6 14 52 2.0
75PAR30NSP 43
4
13 1.50.9 0.9 287 1.41.0 1.0 247 1.41.1 1.1102311.3
CBCP - 13,000 61302.7 1.21.2 1392.3 1.3 1.2 154 2.01.3 1.3 14 98 2.0
Beam - 10 deg. 863 4.51.5 1.5733.6 1.61.5 77 3.2 1.71.6 18 54 2.7
75PAR30NSP-L 217 1.50.9 0.9 199 1.41.0 1.0 171 1.41.1 1.110 160 1.3
CBCP - 9,000 6902.7 1.21.2 96 2.3 1.3 1.2 107 2.01.3 1.3 14 68 2.0
Beam - 10 deg. 8444.5 1.51.5 51 3.6 1.61.5 53.3 3.2 1.71.6 18 372.7
D = 3 FTD = 4 FTD = 5 FT
PAR30
Spot Lamps
HF.C.LWSF.C. LWSF.C.LWS F.C.
Clg.
Ht.
Dia. &
Spacing
Walls and Vertical Objects
Horizontal Surfaces
HF.C.LWSF.C. LWSF.C.LWS F.C.
Clg.
Ht.
Dia. &
Spacing
Walls and Vertical Objects
Horizontal Surfaces
HF.C.LWSF.C. LWSF.C.LWS F.C.
Clg.
Ht.
Dia. &
Spacing
Walls and Vertical Objects
Horizontal Surfaces