Progressive Industries, Inc. Electrical Management System Operating Instructions for: Model EMS-PT50C Rated at 120V/50A Manufactured by: Progressive Industries, Inc. 414B Airport Boulevard Morrisville, NC 27560 (919) 462-8280 www.progressiveindustries.net Proudly manufactured in the U.S.A.
Features High/Low Voltage Protection Whenever AC power falls below 104 volts, or rises above 132 volts, the EMS automatically shuts down power to the RV. The EMS will monitor the power and once the AC power rises above 104 volts, or drops below the 132 volt level, the time delay indictor flashes for the preset time and then automatically restores power to the RV. Time Delay for A/C Compressor If AC power is interrupted, or the EMS detects a fault condition, the built in time delay is activated.
Warnings • Do not exceed the rating on the EMS for any reason, however, these devices are designed to be reduced down to 120V/15A, and still maintain full protection. • Do not modify the EMS in any way, this will void the warranty, compromise protection, and could result in possible shock, and/or a fire hazard. • It is important to always check the pedestal power outlet for charring; this condition means that the AC receptacle is providing a weak connection.
Operating Instructions 1. 2. 3. 4. 5. 6. Plug into AC power. Digital display will read 888 for one second then begin scrolling the voltage, amps, line frequency, and error code(s). In addition, the time delay light will flash in the bottom right corner of the display. The EMS will read L-1, and then give you a 3-digit number which is your line voltage. Next, it will give you an “OA” reading. This is the amp reading; however, it will read zero until the time delay is complete.
Error Code Chart E-0 E-1 Normal Condition Reverse Polarity Condition (hot and neutral wires Reversed) E-2 Open Ground (means no ground wire connection) E-3 Line 1 Voltage High (Line 1 voltage above 132 volts) E-4 Line 1 Voltage Low (Line 1 voltage below 104 volts) E-5 Line 2 Voltage High (Line 2 voltage above 132 volts) E-6 Line 2 Voltage Low (Line 2 voltage below 104 volts) E-7 Line Frequency High (Line frequency above 69 cycles per second) E-8 Line Frequency Low (Line frequency below 51 cycles per second
Troubleshooting Guide In order for the on-call Technician to troubleshoot the problem(s) you are experiencing and render the best possible solution, it is necessary that you be at your RV when you place your call. 1. If the display is illuminated and scrolling information, note the Error Code. If there is an Error Code of 1-8, the device will interrupt the power. See Error Chart for definition of AC power problem.
Progressive Industries Warranty Progressive Industries warrants its products are free from defects in materials and workmanship for the life of the unit. This is in lieu of all other warranties, obligations or liabilities expressed by the company. In the event that a properly installed EMS proves defective under normal use, Progressive Industries will repair or replace the device at its discretion. For Technical Support, please call (919) 462-8280.