Mounting and Connecting to the OMEGA
Refer to System Installation Warnings earlier in this manual before proceeding.
Either version of the OMEGA may be mounted on a shelf or wall. If mounting on a shelf,
ensure that it is sturdy enough to support the OMEGA. If wall mounting, attach the supplied
brackets and remove the rubber feet. Then, using appropriate screws and/or wall anchors,
attach the OMEGA to the wall.
Connecting to the OMEGA Lite
POS Connection
Referring to the OMEGA Lite Diagram on the next page, connect to Port 4, next to the
Network Connection.
If connecting to a standard PC – Use a standard NULL-MODEM cable.
If connecting to a VeriFone POS system – Referring to the VeriFone RS232
Adaptor Diagram, which follows, use an RJ45 to DB9 (male) adaptor to
connect to the VeriFone cable.
If connecting to other non-PC POS systems – Referring to the RS232 to OMEGA
Diagram, which follows, connect using the specified connector pin-outs.
Dispenser Connection
Referring to the OMEGA Lite Diagram, which follows, identify Port 1,Port 2 and Port 3.
These are all DB9 (male) connectors which connect directly to a Gilbarco Universal
Data Distribution Box (TW). A standard serial cable, using all nine wires, may be used
to connect the OMEGA Lite to the Gilbarco DBox. Using all three channels, the
OMEGA Lite can control up to 36 dispensers.
Port 1 controls the dispensers on Channel 1.
Port 2 controls the dispensers on Channel 2.
Port 3 controls the dispensers on Channel 3.
See Start-Up and Configuration in the next section of this manual for information on
logging in to the OMEGA2 web site to configure the dispensers.