Specification Sheet

SPECIFICATION
RSP-2000-12 RSP-2000-24
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
AC CURRENT (Typ.)
Note.5
12V 24V
100A 80A
0 ~ 100A 0 ~ 80A
1200W 1920W
150mVp-p
10.5 ~ 14V
200mVp-p
21 ~ 28V
±2.0% ±1.0%
±1.0%
±1.0%
1500ms, 60ms/230VAC at full load
16ms/230VAC at 75% load 10ms/230VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
0.97/230VAC at full load
87%
COLD START 50A
13A/115VAC 7A/230VAC 16A/115VAC 10A/230VAC 16A/115VAC 10A/230VAC
<2mA / 240VAC
RSP-2000-48
48V
42A
0 ~ 42A
2016W
300mVp-p
42 ~ 56V
±1.0%
±0.5% ±0.5%
±0.5% ±0.5%
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
90.5% 92%
Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover
OVER TEMPERATURE
OVERLOAD
OVER VOLTAGE
105 ~ 125% rated output power
14.7 ~ 17.5V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
29.5 ~ 35V 57.6 ~ 67.2V
PROTECTION
DC OK SIGNAL
REMOTE SENSE
REMOTE ON-OFF CONTROL
AUXILIARY POWER
CURRENT SHARING
The isolated TTL signal out. Please refer to the Function Manual.
Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual.
By electrical signal or dry contact Power ON:open Power OFF:short. Please refer to the Function Manual.
5V @ 0.3A, 12V @ 0.8A
Up to 8000W or (3+1) units. Please refer to the Function Manual.
FUNCTION
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-35 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
ENVIRONMENT
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
MTBF
DIMENSION
PACKING
OTHERS
159K hrs min. Telcordia SR-332 (Bellcore) ; 46.3K hrs min. MIL-HDBK-217F (25 )7F (25 )℃℃
295*127*41mm (L*W*H)
SAFETY &
EMC
(Note 4)
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
1.95Kg; 6pcs/12.7Kg/1.15CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.720 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
2000W Power Supply with Single Output
RSP-2000 series
Parameter
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN55024 , EN61204-3, EN61000-6-2
Standard
Standard
EN55022 (CISPR22) / EN55011 (CISPR11)
EN55022 (CISPR22) / EN55011 (CISPR11)
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level / Note
Test Level / Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
Level 4, 2KV/Line-Line 4KV/Line-Earth
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Class A
Class A
-----
-----
EMC IMMUNITY
EMC EMISSION
Adjustment of output voltage is allowable to 40 ~ 115% of nominal output voltage. Please refer to the Function Manual.
OUTPUT VOLTAGE PROGRAMMABLE(PV)
File Name:RSP-2000-SPEC 2016-01-20