Manual

12
2.2 PULSE-TRONIC CHARGE
2.2.1 CHARGE FUNCTION MODES
There are various Pulse Tronic charge procedures that depend on the battery
construction technology (T) and the charge current (C). When the battery is charged,
the battery charger switches automatically to maintenance mode.
a) AUTOMATIC PULSE-TRONIC
(T) AUTO (C) AUTO
Both the identification of the battery construction technology (fig. A.16)
and the current needed to charge it function in automatic mode (fig. A.6).
This function mode is recommended when there is no information on the
battery type.
b) AUTOMATIC PULSE-TRONIC AT LOW
TEMPERATURES (COLD fig. A.7)
(T) AUTO d (C) AUTO
Mode that improves the battery charge when the temperature is very low.
Low temperature can influence the chemical structure of the battery
components, therefore this function optimises the charge process according
to this reduction in temperature.
This feature applies to the WET, AGM, PbCa batteries only.
When the battery is charged, the battery charger switches automatically to
maintenance mode.
DISPLAY
CHARGE
RATE
MODE
AUTOMATIC
AUTOMATIC
WINTER
T<0°C
MANUAL
CURRENT SELECTION
Ah
DISPLAY
AUTOMATIC
QUICK CHARGE
MANUAL
BATTERY TYPE SELECTION