Manual

18
2.4 BATTERY MAINTENANCE
The device has two advanced operating modes for the maintenance of 6/12/24V
batteries (ADVANCED PROGRAMS), press and hold the “MODE”button for 3
seconds (fig. A.22) recommended for AGM and WET type batteries:
DESULFATION: recovery of sulphated batteries (fig. A.10);
EQUALIZATION: reset of optimal battery conditions (fig. A.9).
On completing the selected process, disconnect the power cable from the mains
socket and disconnect the clamps from the battery terminals.
BUTTON LOCK. It is possible to lock and unlock the setting by simultaneously
pressing and holding the “BATTERY VOLTAGE” (fig. A.21) and “CHARGE RATE”
(fig. A.23) buttons for 3 seconds, and (fig. A.2) (fig. A.4) “LOK on” and“LOK off”
will appear respectively on the display.
TO EXIT THE “ADVANCED PROGRAMS” MENU:
Press and hold the “MODE” button (fig. A.22) for 3 seconds.
3"
BEEP
MENU
ADVANCED
PROGRAMS
3"
DISPLAY
3"
DISPLAY
3"
BEEP
DISPLAY
MODE
MODE
MODE
BATTERY VOLTAGE CHARGE RATE
BATTERY VOLTAGE CHARGE RATE
ADVANCED MENU SELECTION
KEYBOARD LOCK
KEYBOARD UNLOCK
EXIT – ADVANCED MENU
FUNCTION SELECTION
3"
BEEP
MENU
ADVANCED
PROGRAMS
3"
DISPLAY
3"
DISPLAY
3"
BEEP
DISPLAY
MODE
MODE
MODE
BATTERY VOLTAGE CHARGE RATE
BATTERY VOLTAGE CHARGE RATE
ADVANCED MENU SELECTION
KEYBOARD LOCK
KEYBOARD UNLOCK
EXIT – ADVANCED MENU
FUNCTION SELECTION