Manual

FAULTS & ERRORS
Therearethreeerrorcodesthatmaybedisplayed.Thesewillbedisplayedinthe
followingway:
LCD Power On LED Fault Remedy
Err SlowFlashing Shortcircuitorreverse
connection of the clips
Check clips are not
touching each other
OR
Check the clips are
correctly connected
to the battery
F01 FastFlashing Bulkcharginghas
timed out and stopped
after 22 hours
Batterymaybefaulty
SlowFlashing Thechargerhas
entered recondition
mode 3 times and
has timed out
Batterymaybefaulty
and may need replacing
OR
Thereisaloadonthe
battery causing the
batterytofailAnalysis
OTP FastFlashing Thechargerhas
overheatedandhas
switchedoff
Ensureadequate
ventilationaround
the charger
OLC FastFlashing Sensorwiresarenot
connected to the
positive/negative
connections
IfDCleadshavebeen
cutforhardwiring,check
sensorwiresareincluded
inbothpositive&negative
connections(Refer
topage13,point1)
OCP FastFlashing Thechargerhas
encountered an error
ContactBrown&Watson
International
18