UNDERSTANDING YOUR INVERTER
These inverters are equipped with an audible alarm and a multi-function LCD screen
with selection buttons allowing you to monitor the inverter’s performance. During
normal operation, the LCD screen will default to the VOLTS display (input battery
voltage). Alternative information can be displayed by pressing the relevant buttons:
VOLTS: Displays input battery voltage
WATTS & LOAD%: Displays the amount of power being drawn by the appliance
(in Watts) & indicates the percentage of total capacity being drawn by the appliance
(Load). Press the WATTS/LOAD% button on the front of the unit to alternate between
Watts and Load display information.
ECO: Displays ECO mode status settings.
In the event of a fault or error, the alarm will sound and the LCD screen will display
one of several fault codes.
STATUS CODE REMOTE L.E.D SIGNAL ALARM
Operating from mains
AC power MAINS AC Green
Operating from
DC power INVERTER Green
Low Battery Voltage Lb Green
ON
Low Battery
Voltage Shutdown Lb Green/Red (Flashing)
/ ON
Over Temperature
Shutdown OTP Red
ON
Output Short Circuit OSP Red
ON
Overload Shutdown OPP Red (Flashing)
ON
High Battery
Voltage Shutdown Hb Green (Flashing)
ON
Note: In the event of the RCD switch tripping the inverter will not sound an alarm,
a green indicator will be present above the switch. This indicates the AC mains output
is off and safe