Product Manual
LVD ACTIVITY/STATUS
LED SIGNAL STATUS REMEDY
Green Monitoring No action required
Red Load Disconnect Recharge your battery or press the reset button
to reconnect the LVD manually prior to reaching
the automatic reconnect point (13V)
Red (Flashing) Overload
Green (Flashing) Check Load
Red / Green (Flashing) / Fuse Failure Replace fuse, check wiring for short circuit
OFF No Power to LVD No action required
SPECIFICATIONS
P/No: LVD30 LVD50
Output Current 30A 50A
Input Voltage 10–16V 10–16V
Current Draw 10mA 10mA
LVD Disconnect 10V, 10.5V, 11V & 12V 10V, 10.5V, 11V & 12V
(Disconnect delay 60 seconds)
LVD Reconnect 13V 13V
Size (mm) 108 x 66 x 38 180 x 66 x 38
Weight 0.3kg 0.5kg
Fuse 1 x 30A Blade Fuse 2 x 30A Blade Fuse
7
Check the load connected to the LVD,
overload situation has occurred due to
excessive current draw
LVD30-LVD50 Instruction Manual 7-9-11_Layout 1 7/09/11 4:57 PM Page 8