INTELLI-RV 12V POWER MANAGEMENT SYSTEM IMAGE TO BE UPDATED P/No.
CONTENTS 1. SYSTEM INTRODUCTION PM100.................................3 1.1 1.2 1.3 1.4 1.5 Features Battery Charger of stationery/service battery Battery Low Voltage Protection Voltage Charging Relay (VCR) Specification 3 5 5 6 6 2. STRUCTURE.................................................................8 3. OPERATION.................................................................9 3.1 Configuration 3.2 Wiring 3.3 LED display 9 9 10 4. DISPLAY EXPLANATION AND TROUBLESHOOTING ...
1. System Introduction PM100 PM100 is designed for use in caravans or motor homes. The PM100 is designed for an easy installation and a user-friendly interface without the need for a highly tailored cable harness. IMAGE TO BE UPDATED PM100 unit 1.
WORKING PRINCIPLE 1 + _ AC/DC L N AC IN 2 VCR Shunt 1 2 Shunt BLVP F2 35A - - - - - - - - - - 15A DC- 10A DC- LOAD1~LOAD4 15A*4 LOAD5~LOAD10 10A*6 F13 15A F12 15A F11 15A F10 15A F9 10A F8 10A + + + + + + 15A DC+ F7 10A F6 10A F5 10A F4 10A + + + + 10A DC+ LOAD1~LOAD4 LOAD5~LOAD10 15A*4 10A*6 Load+ F19 35A Load- Load BAT+ BAT- Caravan Battery SBAT- SBAT+ Car Battery MULTIPLE INPUTS PM100 has two inputs: AC mains and auxiliary (AUX).
1.2 Battery Charger of stationery/service battery The charger automatically starts when the power is connected, either from grid or generator. With multiple charging stages (soft start, bulk, absorption, float, recycle), PM100 is designed to fully charge the battery quickly. To guarantee the optimal charging for batteries of different states, the PM100 features a Microprocessor-controlled charging algorithm.
1.4 Voltage Charging Relay (VCR, also known as a VSR) PM100 has a built-in voltage charging relay (VCR), which offers a convenient source to charge the service battery by alternator whilst engine is running. When the starter battery reaches 13.4VDC with threshold time delay, the VCR will charge the service battery from the alternator. VCR will continue the charging until the starter battery voltage drops under 12.8VDC.
Model PM100 OTHERS Battery Disconnect (LVD) Current draw on battery Fused outputs Disconnect voltage 10.5VDC Delay off time 60Sec Reconnect voltage 11.5VDC 240VAC is off, no vehicle charging 200mA LVD battery <10.5V. Current draw on battery 60mA LVD battery <10.0V.
2. Structure 70 270 260 38,5 Ø5 120 196,9 11,5 11,5 53 76 12,5 6 4-̘ 14 25 66 260 66 103 10.
3. Operation 3.1 Configuration 146,9 70 SIDE PANEL 1 70 2 3 4 5 6 7 No.
3.3 LED display 1 2 3 4 No. 1 2 LED Mains Starter Bat.
4. Display explanation and Troubleshooting Illuminating Dim Flash * When the PM100 detects the voltage of the starter battery is below 2V, it assumes that starter battery is not connected to our system. Mains Str Bat. Charge Fault Description Solutions Power supply mode (PS mode) AC grid is working as the source of power supply. No starter battery connected AC grid is working as the source of power supply. Starter battery has been connected.
Mains Str Bat. Charge Fault Description Solutions Troubleshooting "FAULT" flashes once every sec. Service battery low voltage alarm. 10V≤ Service battery voltage <10.5V. No starter battery connected. "FAULT" flashes once every sec. “Starter Bat.”flashes twice every sec. Service battery low voltage alarm. 10V≤ Service battery voltage <10.5V. Starter batter has been connected, but VCR disconnect. "FAULT" flashes twice every cycle. Service battery high voltage alarm. Service battery voltage≥16V.
NOTES
WARRANTY STATEMENT Applicable only to product sold in Australia Brown & Watson International Pty Ltd of 1500 Ferntree Gully Road, Knoxfield, Vic.