User`s guide
english
16
User’s Guide – Getting to know the projector
F35/FL35  
user’s guide - Getting to know the projector
4.2  Indicators
System status indicators are located right of the keypad on the back of the projector. Figure 
4-4 shows the three status indicators – one for each lamp and one for the system status.
Figure 4-4. The lamp indicators
For the lamp indicators the following apply:
-  PERMANENT GREEN LIGHT: The lamp is on and operating normally.
-  PERMANENT YELLOW LIGHT: The lamp is off. The lamp may be disabled in the menu or 
the system is in standby.
-  PERMANENT RED LIGHT: Lamp life has expired, lamp is not igniting or lamp door is 
open. If the lamp life has expired, please change projection lamp immediately. Failing to 
change lamp may lead to lamp explosion. Please replace with original projectiondesign 
replacement lamp.
-  FLASHING YELLOW LIGHT: The lamp is cooling down. The total cooling down time is 
approx. 45 seconds.
-  NO LIGHT: No lamp inserted.
The replacement lamps must be purchased from an authorized projectiondesign dealer 
for the warranty of the product to be valid. Using lamps from any other after market 
supplier will void the warranty.
4.2.1  The status indicator
-  PERMANENT GREEN LIGHT: The projector is turned on and in normal operation.
-  PERMANENT YELLOW LIGHT: The projector is in standby mode. If the projector was 
powered off by the power saving feature (DPMS), it will automatically power on when you 
connect a valid source. 
-  FLASHING YELLOW LIGHT: Please wait. The yellow light will flash a period after power 
cord is connected (20-30 sec.), and a period after going to standby mode while lamp is 
cooling down (approximately 45 sec.). The projector may not be turned on again until the 
light has turned to permanent yellow.
-  FLASHING RED LIGHT: Projector is overheated. Turn off immediately! Check if air inlets 
are covered or if ambient temperature is outside specifications. The projector cannot be 
restarted until the power cord is disconnected and reconnected again. If the projector 
continues to flash red, you will need to return the unit for service.
*  Pictures show backpanel of projector with UHP lamps.  
LED illumination projectors have one indicator lamp (LED), instead of two (LAMP 1, LAMP 2).