MT-1505 Automatic Pocket Meter User’s Manual st , 1 Edition 2012 ©2012 Copyright by Prokit’s Industries Co., Ltd.
Front panel description Introduction This unique meter has a full complement of features in a compact package only 3/8 inch deep and weighing less than 3 oz. The essential shirt-pocket size meter for portability .Model MT-1505 is fully auto-ranging and has an oversized, easy-to-read digital display. It offers the Auto-Select feature that guides the meter to display AC volts, DC volts or resistance based on what you are measuring. This meter is fully rated to CAT III levels.
AC voltages, capacitance, frequency, diode and continuity plus safety extras such as transient protection to 4 kV and overload protection to either 600 V. Safety Information The MT-1505 Automatic Pocket Meter is certified for EN61010-1:2001; CAT II 450 V, CAT III 300 V, class 2 and pollution deg. 2. This instrument is EN61010-1 certified for Installation Category II (600V). It may only be used to make measurements on energy limited circuits within equipment and not directly connected to mains.
Turning the Meter On and Off Press the Power button for approximately 3 seconds to turn the meter on. To turn the meter off, press the Power button until the display goes blank.
Continuity & diode With Auto on the LCD, switch to Continuity function. The meter will show a symbol of diode display, then press the power button momentarily 1 times to enter into continuity function with a symbol of speaker. A continuous beep tone indicates a closed circuit. Continuity is used for checking wiring connections and operation of switches. Frequency With Auto on the LCD, switch to frequency function, the meter displays Hz when it is ready. This function is auto-ranging.
Probe-Contact EF-Detection For more precise indication of live wires, such as distinguishing between live and ground sockets, use the V ac manual function selection for direct contact voltage measurements. Product Maintenance Maintenance Do not attempt to repair this meter. It contains no user serviceable parts. Repair or servicing should only be performed by qualified personnel. Cleaning periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents.
Battery Replacement If the meter starts up with persistent resetting display or with low battery icon turns on, replace the battery. The meter uses one 3 V coin battery IEC-CR2032. To replace the battery, turn off the meter. Disconnect the test leads from live circuits. Loosen the screw on the case bottom. Lift the end of the case bottom nearest the input test leads until it unsnaps from the case top. Replace the battery cover and tighten the screw. Recycle the battery using approved methods.
Sensing: Average sensing Overload Protection: 600V dc and V ac rms Low Battery: Below approx. 2.4 V Power Supply: 3 V standard button battery x 1 (IEC-CR2032) Power Consumption (typical): 1.2 mA APO Consumption (typical): 2.0 μA APO Timing: Idle for 10 minutes Dimension / Weight: L115 mm x W 57 mm x H 12 mm / Approx.
Auto-select DC Voltage Range Resolution 4V 1mV 40V 10mV 400V 100mV 600V 1V Accuracy ±(0.7%rd+4d) ±(0.8%rd+5d) Input Impedance: 10 MΩ, Max Input:600V DC AC Voltage Range Resolution 4V 1mV 40V 10mV 400V 100mV 600V 1V Accuracy ±(0.8%rd+4d) ±(1.2%rd+4d) Range Accuracy: 40 Hz – 1K Hz, Input Impedance: 10 MΩ, Max Input: 600V AC Resistance Range Resolution 400Ω 0.1Ω 4KΩ 1Ω 40KΩ 10Ω 400KΩ 100Ω Accuracy ±(0.
4MΩ 1KΩ 40MΩ 10KΩ ±(2.0%rd+5d) Max Input: 250V DC/AC Capacitance Range 1) 2) 3) 4) Resolution 40nF 10pF 400nF 0.1nF 4uF 1nF 40uF 10nF 200uF 100nF Accuracy ±(4.5%rd+6d) Accuracy below 40 nF is not specified Top range. Updates > 1 minute on large values Specified with battery voltage above 2.8 V (half full battery). Accuracy decreases gradually to 12% at low battery warning voltage of approx. 2.4 V. Max Input: 250V DC/AC Frequency Range Resolution Accuracy 40Hz 0.01Hz ±(1.
4MHz 1KHz 10MHz 10KHz ±(1.5%rd+5d) Max Input: 250V DC/AC EF Detection Indication: Bar graph segments & audible beep tones proportional to field strength Detection Frequency: 50/60 Hz Detection Antenna: Top right corner of the meter Typical Voltage Bar Graph Indication 15V-55V - 30V-85V -- 55V-145V --- ABOVE120V ---- Audible Continuity Tester Resolution:<100Ω Open Circuit Voltage: 0.5 V DC typical Max Input:250V DC/AC Diode Test Range: 0.
MT-1505 智能口袋型電錶 使用說明書 為了確保人身安全和防止損壞儀錶,使用者在使用之前必須仔 細閱讀本說手冊中的安全注意事項。 1. 接通儀錶電源時顯示 符號說明電池工作電壓低應及 時更換電池。 2. 檢查表筆,絕緣應完好無損,無斷線、脫頭和銅線裸露現 象。 3. 檢查儀錶殼體,應無破裂損壞現象。 4. 按測量需要將檔位元開關置於正確位置。 5. 表筆接入被測電路時應先接黑表筆,表筆與被測電路分離 時應先斷開紅表筆。 6. 當改變功能或檔位時任何一根表筆均要與被測電路斷開。 7. 為避免損壞儀錶,不要輸入超每個功能檔位所規定的最大 值。 8. 在測量高電壓時,應謹慎小心避免觸電,特別是不要接觸 被測電路並保持一定距離,以確保人身安全。 9. 當使用儀錶進行測量時,絕對不要打開後蓋,以免有觸電 危險。 10. 在打開後蓋更換電池前,應將表筆離開被測電路,並關斷 電源。 11. 在進行電流測量時,應確保儀錶是串接在被測回路中。 12. 當你的儀錶或手是濕的時候請勿使用儀錶進行測量。 13.
14. 雖然有自動關機功能,但測量完畢後,還是要即刻關斷電 源。 15. 不要改動儀錶內部電路,以免損壞儀錶及安全。 16. 應避免在直射陽光、高溫、高濕、易燃易爆及蒸汽和粉塵 大的環境中使用或存放。 一、特點 此卡片表是擁有自動測量功能(ACV、DCV、OHM)專利技術 的智慧數位電錶。採用大螢幕LCD 4000位元顯示。可用來測量 交直流電壓,電阻,電容,頻率,二極體,通斷等。具有自動 選擇,自動檔位,自動關機及全功能符號顯示等功能。該儀錶 具有結構精巧,操作容易,攜帶方便等優點,是電氣測量的理 想工具,該產品具有以下特點: 安全設計符合IEC1010國際標準。全系列產品通過CE國際安 全認證。 殼體採用ABS阻燃材料,安全更有保證。 智慧自動選擇測量(ACV、DCV、OHM), 10分鐘自動關機 功能 全功能、檔位元超載保護,保護電壓250V有效值。 高內阻保證最小的測量誤差(10 MΩ)液晶顯示字高 18mm。 二、一般特性 2.1:安全規範:IEC1010- Ⅱ級 2.2:最大顯示:3999 2.3:採樣速率:每秒3次 2.4:過量程顯示:顯示OL,並有蜂鳴器聲音提示 2.
2.8:工作環境:0-40℃,相對濕度<75% 2.9:儲存環境:溫度-10-50℃,相對濕度<75% 2.10:電源:3V鈕扣電池一顆。型式:CR2032,功耗:約2mW 2.11: 外形尺寸:114.8mm X 56.9mm X 11.6mm 2.12:重量:約75g(包括電池和表筆) 2.13:附件:透明蓋,使用說明書,彩盒包裝。 三、使用方法 3-1:直流電壓(DCV) 量程 解析度 準確度 4V 1mV ±(0.7%rd+4d) 40V 10mV 400V 100mV 600V 1V ±(0.
40V 10mV 400V 100mV 600V 1V ±(1.2%rd+4d) 輸入阻抗10MΩ,最大輸入電壓600V DC或AC(有效值)。 頻率範圍:40Hz-1KHz. 回應:平均值(正弦波有效值) 當輸入的測量電壓高於36V安全電壓時,高壓警示符號 “ OL "會出現,提示安全操作。 2-1:按壓儀錶中心的矽橡膠按鍵3秒以上開機。 2-2:將功能選擇開關旋至AUTO的位置 2-3:用紅、黑表筆分別接觸到被測電源的兩端。 2-4:此時液晶顯示幕顯示出被測信號的數值、單位、和極性等。 3-3:電阻(OHM) 檔位 解析度 準確度 400Ω 0.1Ω 4KΩ 1Ω ±(0.8%rd+2d) 40KΩ 10Ω 400KΩ 100Ω 4MΩ 1KΩ 40MΩ 10KΩ ±(2.0%rd+5d) 開路電壓約為0.
4uF 1nF 40uF 10nF 200uF 100nF 超載保護:250V DC 或 AC(有效值) 4-1:按壓儀錶中心的矽橡膠按鍵3秒以上開機。 4-2:將功能選擇開關旋至CAP的位置. 4-3:用紅、黑表筆分別接觸到被測電容的兩端。 4-4:此時液晶顯示幕顯示出被測電容的數值、單位等。 3-5:頻率(FREQ) 檔位 解析度 準確度 40Hz 0.01Hz ±(1.0%rd+5d) 400Hz 0.1Hz 4KHz 1Hz ±(0.5%rd+5d) 40KHz 10Hz 400KHz 100Hz 4MHz 1KHz 10MHz 10KHz ±(1.5%rd+5d) 輸入電壓範圍:0.
3-6:二極體測試 量程 Diode 功能 顯示近似二極體正向 電壓值 正向直流電流約為1mA,反向直流電壓約為0.5V 超載保護:250V DC 或 AC (有效值) 6-1:按壓儀錶中心的矽橡膠按鍵3秒以上開機。 6-2:將功能選擇開關旋至二極體的位置, 6-3:用紅、黑表筆分別接觸到被測二極體的兩端。 6-4:此時液晶顯示幕顯示出被測二極體的數值、單位等。如顯 示OL,則說明二極體和表筆接反,調換表筆即可。 3-7:通斷測試 量程 Beep 解析度 1mV 功能 如果被測線路電阻小於100Ω,儀錶內置蜂 鳴器將發聲 開路電壓約為0.
3-8:非接觸電壓檢測 檔位 功能 NCV 如果被測線路有交流電壓存在,儀錶內置 蜂鳴器將發聲 8-1:按壓儀錶中心的矽橡膠按鍵3秒以上開機。 8-2:將功能選擇開關旋至NCV的位置,這時,手持儀錶,用儀 錶的右上端靠近被測源,如被測源的信號幅度大於15伏的峰 值,則第一條模擬指示會上移到液晶中間位置。 8-3:具體的測試顯示靈敏度和電壓幅度的對應關係,請參照下 表。 檢測範圍 類比指示顯示 15V-55V 30V-85V -55V-145V --ABOVE120V ---- 17
四、保養 4-1:更換電池 在打開底殼之前,應將表筆從測量電路移開,以避免電擊危險。 4-1-1:如果“ "符號出現,表明應該更換鈕扣電池(CR2032).
19