User Manual

AC VOLTAGE
Range Resolution Accuracy
200mV 0.1mV 1.2 of rdg 3digits
2V 1mV
20V 10mV
200V 100mV
0.8 of rdg 3 digits
700V 1V 1.2 of rdg 5 digits
Input Impedance: 10M
Frequency Range: 40Hz to 400Hz (for AC)
Response : Average, calibrated in rms of sine
wave
4.3 CURRENT
DC CURRENT
Range Resolution Accuracy
200A 0.1A
2mA 1A
20mA 10A
0.8 of rdg 3digits
200mA 100A 1.5 of rdg 2digits
10A 10mA 2.0 of rdg 5 digits
- 14-
AC CURRENT
Range Resolution Accuracy
200A 0.1A 2.0 of rdg 3 digits
2mA 1A
20mA 10A
1.0 of rdg 3 digits
200mA 100A 1.8 of rdg 3 digits
10A 10mA 3.0 of rdg 5digits
Overload Protection: F 200mA/250V fuse for
200A to 200mA ranges
Frequency Range: 40Hz to 400Hz (for AC)
Response: Average, Calibrated in rms of sine
wave
4.4 RESISTANCE
Range Resolution Accuracy
200 0.1 0.8 of rdg 3 digits
2K 1 0.8 of rdg 2 digit
20K 10 0.8 of rdg 2 digit
200K 100 0.8 of rdg 2 digit
2M 1K 0.8 of rdg 2 digit
20M 10K 1.0 of rdg 2 digit
200M 100K 5.0 of (rdg-10digits)
10 digits
Maximum Open Circuit Voltage: 700mV (3V for
- 15-