Manual
1-1 General Specifications
• All push button clamp multimeter without rotary switch, more safe and
convenient for operation.
• LCD display digits: 3999 digit large scale LCD readout
• Measuring rate: 5 times / sec.
• Over range display : OL as over range indication
• Auto power off with audible alert and disable function
• Full Icon display with backlight
• Automatic power off time: Approximately 15 minutes after power on.
• Conductor Jaws open up to 42mm
• Low battery indicator:
is displayed. Replace the battery when the indicator
appears in the display
• Power requirement: 3V battery.
1-2 Environmental Conditions
• Indoor Use
• Calibration: One year calibration cycle.
• Operating temperature:
0°C ~ 30°C ( 80% RH)≦
30°C ~ 40°C ( 75% RH)≦
40°C ~ 50°C ( 45%RH)≦
• Storage temperature:
-20 to +60°C, 0 to 80% RH (batteries not fitted).
• Operating altitude: 2000m (6562 ft)
• Overvoltage category: IEC 61010-1 600V CAT. ,Ⅲ
CAT. equipment is designed toⅢ protect against the transients in the equipment
in fixed installations, such as distribution panels, feeders and short branch
circuits and lighting systems in large buildings.
• Conductor Size: 42mm diameter.
• Pollution degree: 2
• EMC: EN 61326-1
• Shock vibration: Sinusoidal vibration per MIL-T-28800E (5 ~ 55 Hz, 3g
maximum).
1