MT-8006B Data Diver User’s Manual 1st Edition, 2013 ©2013 Prokit’s Industries Co., Ltd.
Safety Information Read First Before Use Table 1 describes the international electrical symbols used on the tester and in this manual. Table 1. International Electrical Symbols Warning: Risk of personal injury. See explanations in the manual. Caution: Risk of damage or destruction to equipment or software. See explanations in the manual. Warning: Risk of electric shock. Please keep an eye on the status or function of the equipment while operating.
Standard package: MT-8006B Headphone Angled bed of nails User Manual *1 *1 *1 *1 DESCRIPTION MT-8006B Data Diver is a portable TEL test set used by installers, repair technicians and other authorized personnel for temporary communication and for servicing and installing analog voice telephones.
WARNING: The MT-8006B Data Diver is not designed to meet outside plant requirements. It is recommended that this product not be used outside during adverse and/or wet weather conditions. Legal requirements may exist regarding permission to connect equipment to a Telecom network operated by a public network operator. CAUTION: The operator of this instrument is advised that if the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impaired.
LCD Display: 1. Mute indicator 2. Year / Phone number 3. Month 4. Polarity indicator: red light : The red clip of Angled bed of nails is connect to the + line green light : The red clip of Angled bed of nails is connect to the - line 5. Date 6. Hour 7. Minute 8. Incoming call indicator 9. Sequence of the call in list 10. Voltage LED indicator When incoming call and ringing, the “HI” LED will flash When voltage detected, the “HI” LED will lights up 11. Dialing call indicator 12. LO BATT indicator 13.
Keys introduction Key STO Description Set and Storage ▲/▼ Direction key RCL Recall DEL Delete LNR PSE Last number redial Pause OUT Call out list *,#, 0~9 Number keys Function Press STO key will enter the setting mode, there are 12 setting screen on MT-8006B. Please refer to Operation section. Enter the incoming call list, scroll the numbers in call list and switch the setting screen.
Hand-free function The MT-8006B Data Diver comes with a headset and a phone strap necklace. Connecting them to the headset jack and phone strap hole will give the MT-8006B a hands-free talk function. Please find the phone strap hole and the 2.5 mm jack on the right upper corner of the MT-8006B Data Diver. OPERATION 1. Remove the battery case lid and install 4pcs 1.5V AAA batteries in the battery compartment paying close attention to polarity of battery. 2.
enter the Pause Duration setting. LCD will show “FLASH 3 110“. It means the default pause duration time is 110 ms, Change the value by ▲/▼ keys then press STO to move to the “SET 4 LCD”. LCD light adjust When the “SET 4 LCD” is displayed on LCD, press STO key to enter the LCD light adjust mode. There are 5 LCD light level can be selected. Press ▲/▼ key to change the level then press STO to jump to “SET 5 ALAR” or press DEL to quit.
OFF Mode A. The “OFF” mode can be operated as either power off function or voltage inspection. B. Before testing the line, please slide the switch to the “OFF” position to detect if any voltage exists. When “HI” LED lights up, please disconnect from the tested line to avoid any damage to the Data Diver C. If the “HI” LED does not light up, then you can slide the switch to either “Talk” or “Mon” position for testing operation D.
● LNR →Last Number Redial: MT-8006B is on the Talk position, If a call is not successful and you wish to redial the same number, just press the LNR button. The last number redial function is available in either the Pulse or Tone Mode. The redial memory has a 32-digit capacity.
● LO BATT: If the LO BATT LED lights, that means the user needs to change the battery for fear of losing data. Caution After the battery is removed, the memory of stored numbers will last for 15 seconds only. When changing the battery, please pay attention for the polarity of the battery. If the memory disappears, please follow the previous process as mentioned in this manual to store a number. ● HI →Line high voltage LED indication 1. Set the function switch to “OFF” position. 2.
seconds. 4. Once the incoming number is reached, press LNR key. 5. Set the function to "Talk" mode, and press LNR key, it will automatically dial the number you reached ● Dialing out list checking and dialing 1. Press the OUT key to enter outgoing call list. 2. Use the OUT key or ▲key to view the number in dialing out list. 3. To make an auto speed scroll press the ▲ or ▼ key for 3 seconds. 4. Once the outgoing number is reached, press LNR key. 6.
Battery and fuse replacement If the Data Diver fails to operate properly, or stops working, replace the battery and retest. Do not use rechargeable batteries. To replace the battery: 1. Disconnect the Data Diver from the line and place on a flat work surface with the battery cover up. 2. Use a Phillips screwdriver to remove the two screws from the battery compartment. 3. Remove the battery cover 4. Remove the old batteries and properly discard. 5. Insert 4pcs of 1.
MAINTENANCE WARNING: To avoid electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Disconnect clips from any metallic connections before performing any maintenance. If moisture should get inside the Data Diver, let the Data Diver dry at normal room temperature for 24 hours. DO NOT HEAT THE DATA DIVER. Moisture can provide a leakage path that may conduct hazardous voltages to you. DO NOT USE the Data Diver if wet.
Caution: If the Data Diver connected to a line with voltage over 100V, the fuse will be blown, and it may also caused the IC protection function to start and lock the Data Diver. When it happens, please remove all batteries, and wait for 5-10 minutes until all power is dissipated, then place the batteries back and restart the Data Diver.
Specification ELECTRICAL Loop limit 2 KΩ maximum at 48 Vdc (nominal 20 mA minimum loop current) DC resistance Talk Mode 300Ω typical Monitor impedance Rotary dial output >39kΩ nominal at 1 KHz Pulsing rate 10pps+0.8pps Percent break 60/40%±2% Inter digit interval 1000 ms typical Leakage during Break >130 KΩ DTMF output Tone frequency error ±1.
MT-8006B 電話查線器 安全資訊 使用前請先詳讀 表1.描述電話查線器上或本手冊中,所使用的國際電氣符號。 國際電氣符號 警告:有人身傷害危險。請參閱手冊中的解釋。 小心:有損害或損壞裝置或軟體的危險。請參閱手冊中的解釋。 警告:有觸電危險。 注意:須注意操作時的狀態或功能。 本設備不可連接至公用通信網路,如帶電的電話系統。 警告 不得在超過 100V 的帶電電路上使用本產品。 不得使用已破損的MT-8006B電話查線器 測試導線。使用以前,請檢查 機殼和測試導線是否有破損。 在測試電話電路時,將不使用的測試導線和連接器從MT-8006B電話查線 器上斷開連接。 除非要更換電池,否則不得打開機殼;其中沒有任何用戶可維修的零 件。 在更換電池以前,請斷開所有測試導線的連接。 僅可使用1.
MT-8006B電話查線器 本MT-8006B產品包裝所包含的內容如下列所示: MT-8006B查線器 *1 耳機麥克風 *1 標準美式鱷魚夾 *1 使用手冊 *1 產品特性 MT-8006B是一台用來協助安裝和維修技術人員的攜帶式電話查線器,具有許多 功能特性,足以提供安裝類比式電話線路之所需,防誤測保護功能,能防止因 誤測而造成儀器本身的損壞,同時提供在100V的電壓下僅燒斷保險絲,但不危 害本體的保護功能。 LCD: 可顯示撥出號碼、來電號碼、時間及其他資訊 具有來電顯示功能,能迅速檢測出電話線 手持通話/耳機通話功能,查修使用方便 耳機麥克風及標準美式鱷魚夾線 智慧型省電功能,待機狀態下,可6個月不用更換電池 (注意:電池未隨 機台出貨) 12組雙鍵儲存記憶撥號,每組記憶可達16位數 16個撥出號碼記憶功能,每個號碼可達16位數 DTMF/脈衝式撥號,適合各國不同交換機 具最後號碼重撥功能,最多可撥32位數 支援末碼重撥及預撥號功能 具PBX間隔功能,可在撥號時產生大約1秒鐘的間隔,可用於自動總機電 話的選項或撥打分機 採用高阻抗監聽電路,監聽中不易產生
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22.
LCD 顯示說明 1、 靜音(MUTE)指示燈 2、 年份或電話號碼 3、 月份 4、 極性指示燈: 亮綠燈代表紅色鱷魚夾所接線路為負極端 亮紅燈代表紅色鱷魚夾所接線路為正極端 5 , 6 , 7:日期, 時, 分 8、 來電指示 9、 號碼次序顯示 10、 來電指示和非法線路指示 來電時鈴聲響起時,HI 燈閃亮. 如果是非法線路,HI 燈常亮.
測試模式切換開關 測試模式切換開關位於 MT-8006B 的左側位置,可切換三種模式:電話模式、 待機模式及監聽模式。在電話模式下 MT-8006B 就像一台標準話機,可提供電 話線測試功能,在待機模式下可進行內建功能的設定,在監聽模式 MT-8006B 可監聽線路。 免持聽筒通訊功能 透過 MT-8006B 所提供的耳機麥克風,使用者可以免持聽筒通話,耳機麥克風 的插孔,位於 MT-8006B 右側位置。 本機裝置連接 1. 拆除 MT-8006B 背部上方 2 顆螺絲,取下電池蓋,裝入 4 顆 1.5V AAA 電池。 2.
設定 LCD 亮度調整 當『SET 4 LCD』顯示在 LCD 上時,按下 STO 鍵可進入 LCD 亮度調整模式。 預設的亮度值是 3,共有 5 種亮度可供選擇,使用▲/▼鍵即可進行切換,切 換後的效果會立即顯示在螢幕上,確定後按下 STO 進入下一項設定,或按 DEL 鍵離開設定模式。 注意: “SET 5 ALAR" 並未被使用在本機上,請不要變更此項的設定,請直接按下 STO 鍵跳到“SET 6 IPP" 設定,或按 DEL 鍵離開設定模式。 撥號模式 當 LCD 顯示 “SET 6 IPP" 時,按下 STO 鍵進入本設定,LCD 會顯示“IPP OFF" ,使用▲/▼在 IPP OFF 及 IPP ON 間進行切換,當選擇“IPP OFF"時 撥號模式是 DTMF 模式,選擇“IPP ON" 時撥號模式是脈衝模式。確定後 按下 STO,或按 DEL 鍵離開設定模式。 3、將本機美式鱷魚夾夾到電話線端子,或是待測電話線路上。 通話/ 關機/ 監聽(T / OFF / M) →功能選擇開關: 話機在使用前,要選擇其工作方式,撥動 MT-8006B 上的功能開關 (如右圖),選擇在合適的檔位
Mon —監控功能檔位: 您可以使用“Mon"檔來操作監聽功能,功能開關置於"Mon"(監聽狀態) 檔,MUTE 燈自動亮紅燈起來,如局線有信號則喇叭發出信號音。 注意: 本機於 Talk/ Mon 檔位下,電池需要支援電力給記憶體運作,背光及 Mute 燈也會產生功能,將會造成電力的流失,當機台使用完畢後,請注意將功 能開關設定在“OFF"檔位,避免不必要的電力消耗。 雙音頻/脈沖撥號 本機上設有一個 脈衝撥號/雙音頻撥號 切換開關(PULSE/TONE),在不同 地區可以使用不同的撥號方式, PULSE/TONE 切換開關,撥到左邊代表脈 衝撥號方式,右邊代表雙音頻撥號方式。 STO →記憶儲存撥號鍵: 您可儲存 12 組電話號碼(每組最多 16 數字位元)到數字(0~9)及符號(#, *)。將功能開關置於“OFF"或“Talk"檔,按電話號碼後+“STO"儲 存鍵+所放置的位置(0~9,#,*),則號碼會儲存至所設位置。 RCL →記憶儲存撥號提取鍵: 您可以使用“RCL" 鍵來提取儲存號碼,將功能開關置於“Talk"檔,按 “RCL"+所放置的位置(0~9,#,*)則可自動撥出號碼。
MUTE →靜音開關鍵: 您可以使用“MUTE"鍵暫時關閉送話,使用通話過程中,將 MUTE 開關撥 到左邊,"MUTE" 燈會亮起,可暫時關閉送話,將 MUTE 開關撥到右邊, "MUTE" 燈熄滅,可回復送話。 POL-/G;POL+/R →線路極性判別燈: 當您在查修電話線而無法判別兩根線的正、負極性,可使用本機的極性判別 燈號,確認所夾的線路是否極性正確。 例如:將本機的電信專用夾頭分別夾到電話線上,將功能開關置於“Talk" 檔,面板左上邊 POL 燈亮紅色,表示所夾線路極性正確,紅色鱷魚夾所夾 的線為正極;反之當所夾線路極性錯誤時,面板左上邊 POL 燈亮綠色,表 示紅色鱷魚夾所夾的線為負極,需重新換邊夾上線路再測試。 LO BATT →電池低電壓指示燈: 當您發現面板上“LO BATT"燈亮起時,代表電池低於可工作電壓,此時請 盡快更換電池,必免誤判測試數據或儲存資料遺失。 注意: 本機儲存記憶功能只能維持 15 秒鐘,更換電池時,請注意電池極性不可裝反, 若記憶消失,請依說明書之各項操作重新輸入。 HI →外線線路非法 LED 指示: 功能開關撥到“OFF"檔,將鱷魚夾夾到兩外
1. 2. 3. 4. 5. 按下▲或▼鍵進入來電清單查詢功能。 使用▲或▼鍵查詢所需要的號碼。 按下▲ 或▼鍵超過 3 秒鐘,可進行清單自動跳號查詢功能。 當想要查詢的號碼出現在 LCD 上時,按下 LNR 鍵撥出號碼。 將功能開關推至“Talk"檔,按下 LNR 鍵,即可撥出來電號碼。 去電清單及撥號: 1. 按下 OUT 鍵進入去電清單查詢功能。 2. 使用 OUT 鍵及▲鍵查詢所需要的號碼。 3. 按下▲ 或▼鍵超過 3 秒鐘,可進行清單自動跳號查詢功能。 4. 當想要查詢的號碼出現在 LCD 上時,按下 LNR 鍵撥出號碼。 5. 將功能開關推至“Talk"檔,按下 LNR 鍵,即可撥出去電號碼。 預撥號功能: 在掛機狀態下,通過各數字鍵鍵入要撥出的號碼。若有輸入錯誤,可用 DEL 鍵修改,全部輸入完成以後,按下 LNR 鍵撥出號碼。再將功能開關推至 “Talk"檔,按下 LNR 鍵,即可撥出預撥號碼。 5、Talk 檔位 通話狀態的操作 來電清單及撥號: 1. 按下▲或▼鍵進入來電清單查詢功能。 2. 使用▲或▼鍵查詢所需要的號碼。 3.
電池、保險管更換說明與圖解: 1. 當您的話機 LO BATT 亮 燈或部分功能失效的現 象,可能是電池電量不 足,請更換新電池。用十 字螺絲起子取下電池蓋的 兩個螺絲,拿起電池蓋, 安裝電池,要注意電池的 極性,不要裝錯。(請選 用特性較佳之高性能電 池,確保監聽音量) 圖解 2.
故障現象 死機,不通電 簡易故障排除方法 可能原因 保險管燒斷 / IC 保護鎖機 電話機測試無聲音 線路連接不正確或不牢靠 麥克風不能發話 斷鈴 已開啟閉音功能(MUTE) 1. 電池電量不足 2. 夾到 AC 電源上 關閉閉音功能(MUTE) 1. 更換同型號電池 2. 確定線路是否為電 信訊號線 監控無聲音 1. 監控功能或擴音功能沒 有開啟 2. 電池電量不足 1. 開啟監控功能及擴 音功能 2. 更換同型號電池 雜音 1. 線路連接不牢靠 2. 線路本身電路雜音 1.
產品規格 電氣特性 環路阻抗 最大 2 KΩ/48 VDC (典型環路電流 20mA) 直流阻抗 通話阻抗 300Ω 監聽阻抗 >39kΩ, 1 KHz 脈衝式撥號輸出 脈衝率 10pps+0.8pps 間隙率 60/40%±2% 信號間隔 1000 ms typical 漏阻抗 >130 KΩ 音頻式撥號輸出 音頻誤差率 ±1.5% 最大值 音頻音量 -8±2dBm combined (typical) 音頻訊號音量差 4dB 最大值 記憶撥號 記憶容量 12 組 數字容量 16 位數字 PBX 中斷時間 1~3.6 秒 工作電源 4 顆 1.5V AAA 電池(不附電池) 外殼與尺寸(含金屬掛鉤) 長x 寬 x 高 218.5 x 69.5 x 49 mm / 8.60 x 2.7 x 4.9 inch 重量 208 g (不含電池及配件) PROKIT’S INDUSTRIES CO., LTD. www.prokits.com.tw ©2013 Prokit’s Industries Co., LTD.