Service manual
SE
R
VICE MANUA
L
PFL612W-U
Front
Load
W
ashing Machine
Error
message.
Motor
overheat
protection
or
is
damaged.
Tr
oubleshoo
t
ing:
Error
message.
Wa
ter
level
excee
ds
protection
value.
Tr
oubleshoo
t
ing:
Y
Cut
off
po
wer and
check
if
motor
wi
re
s
are
connected
well
Reconnect
we
ll
Y
Measure
if
th
e
resis
t
ance
of
motor
binding
by mu
ltimete
r,
is
it
as
follo
w
ed?
5-10
[0.75
5 /1.76
(at
20
C)]
;
8
-9[
/
(a
t
20
C)]
;
;
N
Ch
ec
k if water sw
it
ch
ho
se a
nd
air co
ll
ec
tor
are ja
mme
d
Cl
ea
nwatersw
it
ch hose a
nd
air
co
ll
ec
tor
N
Pull
out wa
ter
sw
itc
h inserts and tu
rn
on
po
wer, then set wash mode. wh
il
ewa
te
r
is entering at the position of 3/4 glass
wi
ndo
w,
ch
eck the resistance
bet
ween 11
an
d16,is
it
0?C
he
ck t
he
re
sis
t
an
ce
be
tw
ee
n 11and
14
,
is it infinite?
Re
place water pressure sw
it
ch
N
N
Y
Y
Without star
ti
ng but el
ec
t
rif
y
ing
,me
as
ure
the import voltage
of
inlet valve, is it
bet
w
ee
nAC220-
240
V?
Replace
PCB
Y
Y
Put
the
mot
or
in
normal
tem
per
atur
e
about
ten
minu
t
es,
and
then
tes
t
aga
in. If t
he
res
istan
ce
is n
at
ural, it
is
caused
by
overheated
pr
otectio
n.
Then
check
and dea
lwith
overload,
abnormal
vol
t
age. If not
,
pl
ea
s
e rep
l
ace m
otor
N
Without power ,co
nn
ect inlet pipe
to
inlet
valv
e,
th
en open
th
etapandobserve
if
wa
ter
is ente
ri
ng in dispenser
Y
Replace
inlet
valve
Re
pair wi
res
Pull
out th
ewire
connection
of
motor
and
driving
co
m
puter
board.
Then
check
if
circuit
is
open
by
multimeter