6. Clean heat exchanger.
It is best to use a brush or to rinse thor-
oughly with a hand-held shower.
7.
Replace heat exchanger and lock into
place (turn both lock washers outwards
until they snap into place).
8. Close door in plinth.
The appliance will not operate if the
Condenser indicator is still lit.
Caution! Never operate the dryer
without the heat exchanger.
Emptying the water reservoir
Empty the water reservoir after every drying
cycle.
If the water reservoir is full, an active pro-
gramme will break off automatically and the
warning lamp Water reservoir will illuminate.
In order to continue the programme, the
water reservoir must first be emptied.
Warning! The condensed water is not
suitable for drinking or for preparing
foodstuffs.
1. Take out drawer containing water res-
ervoir completely 1 and pull up the wa-
ter reservoir's drainage pipe as far as it
will go 2.
1.
2.
2.
Pour the condensed water out into a
basin or similar receptacle.
3.
Slide the outlet connections in and refit
the water reservoir.
If the programme has been interrupted
as a result of the water reservoir being
full: Press the Start/Pause button to
continue the drying cycle.
The condensed water can be used as
distilled water, e.g. for steam ironing.
However it must first be filtered (e.g.
with a coffee filter) to remove any resi-
due and small pieces of fluff.
Cleaning the drum
Caution! Do not use abrasives or steel
wool to clean the drum.
Lime in the water or cleaning agents
may form a barely visible lining on the
inside of the drum. The degree to
which the laundry has been dried is
then no longer detected reliably. The
laundry is damper than expected when
removed from the appliance.
Use a standard domestic cleaner (e.g. vine-
gar-based cleaner) to wipe down the inside
of the drum and drum ribs.
Cleaning control panel and
housing
Caution! Do not use furniture cleaners
or aggressive cleaning agents to clean
the machine.
Use a damp cloth to wipe down the control
panel and housing.
WHAT TO DO IF ...
Troubleshooting by yourself
Problem
1)
Possible cause Remedy
31