LED Status Indicator Center
Feature LED Color Function
AC power blue
Auto temp control green with remote temp sensor connected
Active PFC green
Volts display system voltage equal to the charge in the selected profile
Amps display output amperage based on state of charge
Charger output percentage of charge based on state of charge
Self test blue if self test was initiated
OK green following successful self test
Auto Maintain green based on state of charge
Charge green based on state of charge
Conditioning green based on state of charge
16
15
NOTE: This LED configuration indicates that the charger is functioning normally and does not
need any further attention. If the RED “Fault” LED illuminates ,or any of the “Charger Conditions”
LED’s are illuminated, consult the Troubleshooting section of this manual.
OPERATIONAL NOTE: Your ProNauticP Charger has built in safety features that can cause
the unit to shut down if it senses out of parameter operations such as over-voltage and high
temperatures. See the Troubleshooting section of this manual for more details in the event
this occurs.
Optional Remote Display
When the optional remote is installed, it will display the current status of the charger along
with the voltage and amperage.
1. The blue LED is illuminated when the power is ON
2. BACKLIGHT can be set to ON or OFF by toggling the BACKLIGHT button, default is ON
3. ALARM can be silenced or audible by toggling the ALARM button, default is audible
4. During the Auto Maintain (Energy Conservation Mode) only the Power, Auto Maintain and
Standby LED will be on - to view full display, including voltage and current, press any
function button
Optional Remote
Power LED blue indicates power is ON
Fault LED red indicates a fault
Backlight button toggle between ON and OFF by pushing repeatedly, default is ON
Alarm Button toggle between silent and audible by pushing repeatedly, default is audible
Setup selects both “scrolling mode” and activates chosen feature
Enter (see optional remote programming section)
controls for scrolling in “scroll mode”
Setup and Operation
On-Unit LED Indicators and Digital Displays
Feature Color Function
AC power Blue AC power applied
Auto temp control Green Temperature control feature (cooling fan)
active, red flashing if high-temp causes
unit shutdown (see troubleshooting)
Active PFC Green ON when AC power light is on, indicating
power factor correction is functioning
Variable speed Amber Indicates speed of fan during auto temp control
cooling (1,2,3) (feature standard on 20amp and above units).
Charger Mode
Charge Green Charger is in charge mode, actively charging
the battery(s) (bulk charge)
Conditioning Green The unit is in absorption charge mode
Auto Maintain Green The charger is in Auto Maintain
(Energy Conservation Mode)
Equalization Red Equalization charge has been initiated by user
(flooded batteries ONLY, see setup)
Self test Blue Charger is performing a system check
initiated by start-up or manually
OK Green Indicates successful self test
Fault Red Indicates a fault (see troubleshooting)
The ProNauticP is a fully automatic battery charger. The features listed below can be selected
during initial set-up (see Programming section) or upon a new battery installation. Normal
operation does not require any intervention from the user. See the Maintenance section for
information on periodic checks.
Setup and Operation
Battery Profiles Charger Conditions
Charger Mode
Auto MaintainConditioningCharging
AC Power
Auto Temp Control
Active PFC
AmpsVolts
SYSTEM DC OUTPUT LEVELS
Variable Speed Cooling
Self Test
Fault
OK
Standby
AUTO CONSERVATION MODES
100%0%
Battery Health Program
Equalization
Charger Output
SETUP
ENTER
WARNING: HIGH VOLTAGE
ATTENTION : HAUTE TENSION
WARNING: LOW VOLTAGE
ATTENTION : BASSE TENSION
Preset-1
Preset-2
Flooded
Sealed
AGM
GEL
LiFePO4-Lithium
Calcium/Custom
Reverse Polarity
DC Volts Low
DC Volts High
Charger High Temp
Check Fan
Digital
ProMar
Performance Charging
123
AVOID SERIOUS INJURY OR DEATH FROM ELECTRICAL SHOCK. BEFORE OPENING
TURN OFF AC SUPPLY POWER. DO NOT EXPOSE TO RAIN OR SPRAY.
CHOC ELECTRIQUES PEUVENT PROVOQUER LA MORT OU DE SERIEUSE BLESSURES.
AVANT D'OUVRIR LA BOITE, COUPER LE COURANT. NE PAS EXPOSER AUX INTEMPÉRIES.
ELECTRICAL BURN AND SPARK HAZARD. BEFORE OPENING
DISCONNECT CHARGER CONNECTIONS AT BATTERIES.
(DANGER DE BRULURES ELECTRIQUE ET ETINCELLES). AVANT D'OUVRIR LA
BOITE DECONNECTER LES CONNECTIONS ENTRE CHARGEUR ET BATTERIE.
DISPLAY WAKE UP: Press any key; SELF TEST: Hold all keys 5 seconds