Owner manual

Maintenance
This unit is solid state and requires no constant adjustment or constant attention; however,
the following items should be checked:
21
Maintenance Item Start Up Monthly
Verify LED status panel shows no fault condition and indicates
normal operation.
Condition of fuses/breakers check for as-new condition on
fuses (e.g. no discoloration or corrosion) and that a breaker
will manually trip and reset.
Check for proper ventilation and that no debris has collected
on the fan shroud or items have been improperly stored
around the ProNauticP.
Check battery terminal connections (both at battery and the
ProNauticP Charger) for corrosion, clean and reconnect
immediately upon signs of corrosion.
Per manufacturer’s instructions, check and top off batteries
with distilled water. Use of tap or bottled drinking water will
damage battery plates due to mineral content.
Check wire condition, overheating due to excessively long
or too small conductors will result in hardening of the insulation
or even burn marks at connections; If any of these signs
exist, immediately remedy the situation by installing the
proper conductors.
Dimensions
ProNauticP 12volt 10-40 Amp and 24 volt 20 Amp Dimensions Inches (mm)
22
ProNautic 12
40 P
Power Factor Corrected & Global AC Input
3 1/2” (90 mm)
7 3/4” (198 mm)
3 1/2” (90 mm)
8 1/2” (215 mm)
3 3/8” (85 mm) 3 3/8” (85 mm)
10 1/4” (260 mm)