Owner manual

Setup and Operation
NOTE: This LED configuration indicates that the charger is functioning normally and does not
need any further attention. If the RED “Fault” LED illuminates ,or any of the “Charger Conditions”
LED’s are illuminated, consult the Troubleshooting section of this manual.
OPERATIONAL NOTE: Your ProNauticP Charger has built in safety features that can cause
the unit to shut down if it senses out of parameter operations such as over-voltage and
high temperatures. See the Troubleshooting section of this manual for more details in the
event this occurs.
Optional Remote Display
When the optional remote is installed, it will display the current status of the charger along
with the voltage and amperage.
1. The blue LED is illuminated when the power is ON
2. BACKLIGHT can be set to ON or OFF by toggling the BACKLIGHT button, default is ON
3. ALARM can be silenced or audible by toggling the ALARM button, default is audible
15
Optional Remote
Power LED blue indicates power is ON
Fault LED red indicates a fault
Backlight button toggle between ON and OFF by pushing repeatedly, default is ON
Alarm Button toggle between silent and audible by pushing repeatedly, default is audible
Setup selects both “scrolling mode” and activates chosen feature
Enter (see optional remote programming section
controls for scrolling in “scroll mode”
16
Setup and Operation
On-Unit LED Indicators and Digital Displays
Feature Color Function
AC power Blue AC power applied
Auto temp control Green Temperature control feature (cooling fan)
active, red flashing if high-temp causes
unit shutdown (see troubleshooting)
Active PFC Green ON when AC power light is on, indicating
power factor correction is functioning
Variable speed Amber Indicates speed of fan during auto temp control
cooling (1,2,3) (feature syandard on 20amp and above units).
Charger Mode
Charge Green Charger is in charge mode, actively charging
the battery(s) (bulk charge)
Conditioning Green The unit is in absorption charge mode
Ready Green The charger is in float charge mode
Equalization Red Equalization charge has been initiated by user
(flooded batteries ONLY, see setup)
Self test Blue Charger is performing a system check
initiated by start-up or manually
OK Green Indicates successful self test
Fault Red Indicates a fault (see troubleshooting)
The ProNauticP is a fully automatic battery charger. The features listed below can be selected
during initial set-up (see Programming section) or upon a new battery installation. Normal
operation does not require any intervention from the user. See the Maintenance section for
information on periodic checks.
1 2 33
Battery Profiles Charger Conditions
Charger Mode
ReadyConditioningCharging
AC Power
Auto Temp Control
Active PFC
AmpsVolts
SYSTEM DC OUTPUT LEVELS
Variable Speed Cooling
Self Test
Fault
OK
Standby
AUTO CONSERVATION MODES
100%0%
Battery Health Program
Equalization
Charger Output
SETUP
ENTER
SELF TEST: Hold all keys 5 seconds
WARNING: HIGH VOLTAGE
ATTENTION : HAUTE TENSION
WARNING: LOW VOLTAGE
ATTENTION : BASSE TENSION
AVOID SERIOUS INJURY OR DEATH FROM ELECTRICAL SHOCK. BEFORE OPENING
TURN OFF AC SUPPLY POWER. DO NOT EXPOSE TO RAIN OR SPRAY.
CHOC ELECTRIQUES PEUVENT PROVOQUER LA MORT OU DE SERIEUSE BLESSURES.
AVANT D'OUVRIR LA BOITE, COUPER LE COURANT. NE PAS EXPOSER AUX INTEMPÉRIES.
ELECTRICAL BURN AND SPARK HAZARD. BEFORE OPENING
DISCONNECT CHARGER CONNECTIONS AT BATTERIES.
(DANGER DE BRULURES ELECTRIQUE ET ETINCELLES). AVANT D'OUVRIR LA
BOITE DECONNECTER LES CONNECTIONS ENTRE CHARGEUR ET BATTERIE.
Preset-1
Preset-2
Flooded
Sealed
AGM
GEL
LiFePO4-Lithium
Calcium/Custom
Reverse Polarity
DC Volts Low
DC Volts High
Charger High Temp
Check Fan
Digital
ProMar
Performance Charging